Back to all Carrier models Search all database
Carrier 48/50Z HVAC Rooftop PIC Alarm List
Carrier 48/50Z HVAC Rooftop PIC Alarm List Error Codes
Complete alarm and error code reference for the Carrier 48/50Z HVAC Rooftop PIC Alarm List. Browse all 76 documented fault codes below, each linking to a detailed troubleshooting guide.
Search this section
Search Carrier 48/50Z HVAC Rooftop PIC Alarm List
Search all 76 Carrier 48/50Z HVAC Rooftop PIC Alarm List codes without changing pages.
Complete Alarm List
Code ALARM 51
COMPRESSOR A1 FAULT
View solution Code ALARM 52
COMPRESSOR A2 FAULT (Sizes 090,105 Only)
View solution Code ALARM 53
COMPRESSOR A1 STATUS
View solution Code ALARM 55
COMPRESSOR B1 FAULT
View solution Code ALARM 56
COMPRESSOR B2 FAULT (Sizes 090,105 Only)
View solution Code ALARM 57
COMPRESSOR B1 STATUS
View solution Code ALARM 59
THERMISTOR FAILURE SUPPLY AIR
View solution Code ALARM 60
THERMISTOR FAILURE RETURN AIR
View solution Code ALARM 61
OUTSIDE AIR THERMISTOR FAILURE
View solution Code ALARM 62
CIRCUIT A CONDENSER THERMISTOR FAILURE
View solution Code ALARM 63
CIRCUIT B CONDENSER THERMISTOR FAILURE
View solution Code ALARM 64
COMPRESSOR A1 THERMISTOR FAILURE
View solution Code ALARM 65
COMPRESSOR B1 THERMISTOR FAILURE
View solution Code ALARM 66
SPACE THERMISTOR FAILURE
View solution Code ALARM 67
CIRCUIT A DISCHARGE TRANSDUCER FAILURE
View solution Code ALARM 68
CIRCUIT B DISCHARGE TRANSDUCER FAILURE
View solution Code ALARM 69
CIRCUIT A SUCTION TRANSDUCER FAILURE
View solution Code ALARM 70
CIRCUIT B SUCTION TRANSDUCER FAILURE
View solution Code ALARM 71
LOSS OF COMMUNICATION WITH DSIO1
View solution Code ALARM 72
LOSS OF COMMUNICATION WITH DSIO2
View solution Code ALARM 73
LOSS OF COMMUNICATION WITH OPTION BOARD 1 (PSIO2)
View solution Code ALARM 74
LOW PRESSURE CIRCUIT A
View solution Code ALARM 75
LOW PRESSURE CIRCUIT B
View solution Code ALARM 76
HIGH PRESSURE CIRCUIT A
View solution Code ALARM 77
HIGH PRESSURE CIRCUIT B
View solution Code ALARM 78
SUPPLY FAN FAILURE
View solution Code ALARM 80
LOW CIRCUIT A SATURATED SUCTION TEMP
View solution Code ALARM 81
LOW CIRCUIT B SATURATED SUCTION TEMP
View solution Code ALARM 82
HIGH CIRCUIT A SUCTION SUPERHEAT
View solution Code ALARM 83
HIGH CIRCUIT B SUCTION SUPERHEAT
View solution Code ALARM 84
LOW CIRCUIT A SUCTION SUPERHEAT
View solution Code ALARM 85
LOW CIRCUIT B SUCTION SUPERHEAT
View solution Code ALARM 86
ILLEGAL CONFIGURATION (Sizes 030-075 Only)
View solution Code ALARM 88
HYDRONIC COIL FREEZE STAT
View solution Code ALARM 89
PRESSURIZATION
View solution Code ALARM 90
EVACUATION
View solution Code ALARM 91
SMOKE PURGE
View solution Code ALARM 92
FIRE SHUTDOWN
View solution Code ALARM 93
LINKAGE FAILURE
View solution Code ALARM 94
BUILDING PRESSURE
View solution Code ALARM 95
DUCT STATIC PRESSURE
View solution Code ALARM 97
IAQ SET POINT MISCONFIGURED
View solution Code ALERT 150
SUPPLY AIR TEMP LOW LIMIT
View solution Code ALERT 151
SUPPLY AIR TEMP HIGH LIMIT
View solution Code ALERT 152
RETURN AIR TEMP LOW LIMIT
View solution Code ALERT 153
RETURN AIR TEMP HIGH LIMIT
View solution Code ALERT 154
OUTSIDE AIR TEMP LOW LIMIT
View solution Code ALERT 155
OUTSIDE AIR TEMP HIGH LIMIT
View solution Code ALERT 156
SPACE TEMP LOW LIMIT
View solution Code ALERT 157
SPACE TEMP HIGH LIMIT
View solution Code ALERT 158
STATIC PRESSURE LOW LIMIT
View solution Code ALERT 159
STATIC PRESSURE HIGH LIMIT
View solution Code ALERT 160
RELATIVE HUMIDITY LOW LIMIT
View solution Code ALERT 161
RELATIVE HUMIDITY HIGH LIMIT
View solution Code ALERT 162
OUTSIDE AIR RELATIVE HUMIDITY LOW LIMIT
View solution Code ALERT 163
OUTSIDE AIR RELATIVE HUMIDITY HIGH LIMIT
View solution Code ALERT 164
FILTER STATUS
View solution Code ALERT 165
BUILDING PRESSURE LOW LIMIT
View solution Code ALERT 166
BUILDING PRESSURE HIGH LIMIT
View solution Code ALERT 167
OUTSIDE AIR CFM LOW LIMIT
View solution Code ALERT 168
OUTSIDE AIR CFM HIGH LIMIT
View solution Code ALERT 169
INDOOR AIR QUALITY LOW LIMIT
View solution Code ALERT 170
INDOOR AIR QUALITY HIGH LIMIT
View solution Code ALERT 173
RUN HOURS EXCEED SERVICE/MAINT LIMIT
View solution Code A152
Unit down / Critical Serial EEPROM Failure Error
View solution Code T153
Real Time Clock Hardware Failure
View solution Code A154
Serial EEPROM Hardware Failure
View solution Code T155
Serial EEPROM Failure Error
View solution Code A157
A/D Hardware Failure
View solution Code A700
Supply Air Temperature-All Thermistors have failed
View solution Code T701
Supply Air Temperature Thermistor 1 Failure
View solution Code T702
Supply Air Temperature Thermistor 2 Failure
View solution Code T703
Supply Air Temperature Thermistor 3 Failure
View solution Code T705
Cooling Setpoint Ratio Input Error
View solution Code T706
Heating Setpoint Ratio Input Error
View solution Code T707
Limit Switch Thermistor Failure
View solution