代碼 510102: Probe malfunction (spindle probe)
問題描述與安全警告
Chiron Siemens-Control CNC 觸發了嚴重的 Probe malfunction (spindle probe) 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
The probe was not correctly switched on with the "Probe On (spindle probe) ( M94 )" function. Signal sequence for switch-on operation was incorrect. Probe was already directed out during switch-on. After the probe was switched on, a malfunction occurred during the signal exchange between the transmitter (probe) and receiver (OMI). The error has the following effect: Feed Stop No axis movements possible. Read disable Control reads no further program blocks into memory. 1. Check probe (setting, batteries, function, etc.). 2. Check interface (OMI) (contamination, switch setting, connection, etc.) 3. Check the following signals: PLC output signal "Enable measuring device". PLC input signal "Probe OK". PLC input signal "Probe STATUS". CNC input signal " HDI0 (F122.0)". 4. Press [RESET] key. Message is cleared. Error messages Measuring Probe malfunction (spindle probe)
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Chiron Siemens-Control CNC 警報
由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 510102 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 545 Chiron Siemens-Control CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 510102.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026