代码 510117: Moisture sensor mainspindle motor (1)
问题描述与安全警告
Chiron Siemens-Control CNC 触发了严重的 Moisture sensor mainspindle motor (1) 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Moisture sensor on the main spindle motor has responded after a delay time. PLC input signal "Moisture sensor main spindle motor“ is not present. Coolant supply is shut off immediately. (2nd coolant pump and 2nd coolant valve Off) Feed Stop and Spindle Stop, as far as no thread-cutting or tool change is pending. 1. Check moisture sensor on main spindle motor (leakage at Deublin). 2. Check PLC input signal "Moisture sensor main spindle motor". 3. Depending on the sensor type, check the evaluation device in the control cabinet (actuation and setting). 4. As soon as the malfunction has been remedied, switch to "manual mode" and press the following key: [RESET] Message is cleared. Coolant high pressure is activated, but the moisture sensor input = 0 (Moisture monitoring in the spindle) [OK corresponds to high pressure and PLC input signal = 1 ].
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Chiron Siemens-Control CNC 警报
由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 510117 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 545 Chiron Siemens-Control CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 510117.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026