代码 510122: Filter drum soiled / contact manometer defective

问题描述与安全警告

Chiron Siemens-Control CNC 触发了严重的 Filter drum soiled / contact manometer defective 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

The vacuum switch “Contact manometer filter drum“ on the VRF coolant system has been activated 4 times within 2 minutes and initiated “Back flushing“. Filter drum is dirty. The machine will be stopped at the next Rapid feed (G0) or end of program. The coolant pumps are switched off. 1. Switch off the vacuum pump immediately for self-protection against excessively high negative pressure. 2. Check filter drum (dirt, etc.). 3. Check the vacuum switch "Contact manometer filter drum“ and the PLC input signal. 4. As soon as the malfunction has been remedied, press [DELETE ERROR] or [CYCLE START] key. Message is cleared and the machining program can be continued. The filter drum can also be rinsed with the flushing pump for cleaning purpose. With service function M88 and M195 (ON) or M196 (OFF). The vacuum switch “Contact manometer filter drum“ on the VRF coolant system has been activated. Cause 1: VRF drum dirty: Cause 2: Defective manometer: The PLC input signal “Contact manometer filter drum“ is not present. The pressure switch appears to be defective. The machine will be stopped at the next Rapid feed (G0) or end of program. The coolant pumps are switched off. 1. Switch off the vacuum pump immediately for self-protection against excessively high negative pressure. 2. Check the vacuum switch "Contact manometer filter drum“ and the PLC input signal. 3. Once the pressure switch signals OK again (signal state = 1), press the [DELETE ERROR] or [CYCLE START] key. Message is cleared and the machining program can be continued.

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Chiron Siemens-Control CNC 警报

由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 510122 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 545 Chiron Siemens-Control CNC 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code 510122.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.