问题描述与安全警告
Chiron Siemens-Control CNC 触发了严重的 Tool not released (1) 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Actuation "Unclamp tool" was output, but the response from the monitoring function for "Tool clamped" is not correct. The tool has not been correctly unclamped. Cause 1: The error has the following effect: Feed Stop No axis movements possible. Read disable Control reads no further program blocks into memory. If the sensor signals are correct within a monitoring period, the program run is continued. After the monitoring time has elapsed, the machine stops. 1. Check the actuation of the valves "Unclamp tool" and "Clamp tool". 2. Check sensors and corresponding PLC - input signals. 3. Check the voltage value of the analogue sensor. 4. Check the setting of the collet chuck and analogue sensor relative to the adjustment instructions. NOTICE! Adjustment should only be carried out by trained and instructed personnel. 5. As soon as the malfunction is remedied, press the following key: [FEED START] [CYCLE START] Message is cleared and the machining program can be continued. The command "Release tool“ has been output, but the "Tool clamped" pressure switch on the hydraulic unit signals still clamped. PLC input signal "Tool clamped“ is still present. If the messages are in order again within a monitoring time of about 8 seconds, the machine continues on immediately. After the monitoring time has elapsed, the machine stops. Cause 2 with hydraulic clamping system Error messages Tool change Tool not released (1) 1. Check "Tool clamped" pressure switch and the PLC input signal. 2. Check the PLC output signals and the actuation of the "Unclamp tool" and "Clamp tool“ valves.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Chiron Siemens-Control CNC 警报
由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 700239 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 545 Chiron Siemens-Control CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700239.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.