代码 700322: Probe battery alarm
问题描述与安全警告
Chiron Siemens-Control CNC 触发了严重的 Probe battery alarm 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
Operating voltage of the probe falls below a certain limit. PLC input signal "Probe battery alarm" is registered. This message is just for informational purposes and has no effect on the machine. Error messages Measuring Probe battery alarm 1. Change the batteries as soon as possible. 2. Check the PLC input signal "Probe battery alarm". 3. As soon as the malfunction is remedied, press the following key: [RESET] Message is cleared. The batteries can still supply the probe with energy for approx. 1 month with 5% utilization after the first warning signal. A"weak battery" is indicated by the blue blinking status LED at the end of the battery lifetime.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Chiron Siemens-Control CNC 警报
由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 700322 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 545 Chiron Siemens-Control CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700322.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026