代碼 700362: Flow monitor coolant high pressure (1)

問題描述與安全警告

Chiron Siemens-Control CNC 觸發了嚴重的 Flow monitor coolant high pressure (1) 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。

官方故障排除步驟

The coolant (high pressure) was switched on, but after the monitoring delay time elapsed, the PLC input signal "Flow control device, coolant high pressure (1)" is still at signal state [0]. After switching on the coolant, the flow control device is monitored at signal state [1] after a short delay time. Read disable Feed Stop / Spindle Stop The 2nd coolant pump is switched off. 1. Check coolant flow. Possible causes: Patrol filter in pipe to the column is blocked Tool channel blocked Purolator filter blocked Shut-off cock closed Error messages Cooling lubrication Flow monitor coolant high pressure (1) 2. Check the PLC output signal and activation for the 2nd coolant pump and 2nd coolant valve. 3. Check the setting of the flow control device and the coolant flow. 4. Check the PLC input signal “flow control device, coolant high pressure (1)“. 5. Press the following key: [FEED START] Pump is reactivated. Keep pressing the key until the flow control device signals OK. 6. If it doesn't signal OK, when the key is released, the pump is switched off again. To set the flow control device, service function M88 can be programmed. Pump is now no longer switched off in the event of an error. The delay time variable for monitoring during switch-on is set to 5 seconds by default. Flow control device, coolant high pressure (1): DB181.DBD2500 in ms If there is no flow control device in the system, this monitoring function can be deactivated with a machine parameter. Without flow control device coolant high pressure: MD 14512[29] bit 1 = 0

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

關於 Chiron Siemens-Control CNC 警報

由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 700362 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。

完整警報清單: 545 Chiron Siemens-Control CNC 代碼s.

Have a better solution?

Help the industrial community by sharing your repair experience for code 700362.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相關的 Chiron Siemens-Control CNC 代碼