代碼 700746: Turning has not been deactivated --> Switch off main switch
問題描述與安全警告
Chiron Siemens-Control CNC 觸發了嚴重的 Turning has not been deactivated --> Switch off main switch 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
The function "Turning“ was not correctly deactivated for some reason. The coordinate system is still turned. Error messages Swivel head Turning has not been deactivated --> Switch off main switch Feed Stop, since the coordinate system was not correctly switched. This is a serious error and can only be remedied with [Main switch OFF]. and [Main switch ON] If the error is still there, it must be checked whether ASUP_1_M is in the directory of the manufacturer cycles, and whether the _Reset cycle was called in this. When the control is started up, ASUP is run and the coordinate system is put in its original state.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Chiron Siemens-Control CNC 警報
由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 700746 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 545 Chiron Siemens-Control CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 700746.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026