Code 701252: Centric tensioner not released

Issue Description & Safety Warning

The Chiron Siemens-Control CNC has triggered a critical Centric tensioner not released alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

Actuation "Unclamp centric tensioner" is output. PLC input signal "Centric tensioner clamped" is still registered. The error has the following effect: Feed Stop No axis movements possible. Read disable Control reads no further program blocks into memory. If the sensor signals are correct within a monitoring period, the program run is continued. After the monitoring time has elapsed, the machine stops. 1. Check sensor "Centric tensioner clamped" and the PLC input signal. 2. Once the malfunction has been remedied, press [FEED START] key. Message is cleared. If the centric tensioner is in the machining position, the message applies to channel 1 and channel 3. If the centric tensioner is not in the machining position, the message only applies to channel 3.

Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Chiron Siemens-Control CNC Alarms

Chiron controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 701252 on the Siemens-Control CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Chiron's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 545 Chiron Siemens-Control CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 701252.

Manual conversion service

Need a searchable reference for more Chiron Siemens-Control CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Chiron Siemens-Control CNC Codes