代码 701742: Max. super clean water coolant level
问题描述与安全警告
Chiron Siemens-Control CNC 触发了严重的 Max. super clean water coolant level 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
The float switches "Coolant level super-clean water MAX." and "Coolant level chip conveyor MAX." signalled maximum at the same time (signal state = 0). The switch is evaluated with a delay time (T71). The PLC input signal "Coolant level super-clean water MAX." is not present. Feed STOP and Spindle STOP The lifting pump, the 1st coolant pump, the 2nd coolant pump, bed rinsing and the rinsing pump are switched off immediately. Error messages Cooling lubrication Max. super clean water coolant level 1. Check filling level in the clean water tank. 2. Check the float switch "Coolant level clean water MAX" and the PLC input signal. 3. As soon as the malfunction has been remedied, the message is automatically cleared.
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Chiron Siemens-Control CNC 警报
由 Chiron 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 Siemens-Control CNC 出现类似 701742 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 545 Chiron Siemens-Control CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 701742.
Need a searchable reference for more Chiron Siemens-Control CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026