代碼 702321: Profibus slave 24 malfunction (process monitoring system 2)
問題描述與安全警告
Chiron Siemens-Control CNC 觸發了嚴重的 Profibus slave 24 malfunction (process monitoring system 2) 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
a) The Profibus connection between the "machine" and the corresponding module is faulty. b) Hardware was not configured, or it was done incorrectly. c) The module's power supply is missing. Feed Stop, as far as tool change. If a tool change is in progress, this is completed first. 1. a) Check the Profibus machine connection to the module. b) Check the hardware configuration and correct it, if necessary. c) Check the module's power supply. 2. Once the malfunction has been remedied, press [RESET] key Message is cleared. The menu can be found under: Chapter 2.6 ‘Oil/air lubrication’ on page 12
Source: CHIRON Error Message Overview, all series (Siemens control, V2.0.6, 2012)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Chiron Siemens-Control CNC 警報
由 Chiron 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 Siemens-Control CNC 出現類似 702321 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 545 Chiron Siemens-Control CNC 代碼s.