FaultResolve
Back to all Daikin models
Daikin SM-TS3 HVAC Self-Diagnosis

Daikin SM-TS3 HVAC Self-Diagnosis Error Codes

Complete alarm and error code reference for the Daikin SM-TS3 HVAC Self-Diagnosis. Browse all 139 documented fault codes below, each linking to a detailed troubleshooting guide.

Search this section

Search Daikin SM-TS3 HVAC Self-Diagnosis

Search all 139 Daikin SM-TS3 HVAC Self-Diagnosis codes without changing pages.

Search all database

Complete Alarm List

Code A0
External protection device activated
View solution
Code A1
Malfunction of indoor unit PCB
View solution
Code A3
Drain Level Control System Abnormality
View solution
Code A4
Malfunction of freezing protection
View solution
Code A5
High pressure control in heating, freeze-up protection control in cooling
View solution
Code A6
Malfunction of fan motor
View solution
Code A7
Malfunction of swing flap motor
View solution
Code A8
Malfunction of power supply or AC input overcurrent
View solution
Code A9
Malfunction of electronic expansion valve
View solution
Code AA
Heater overheat
View solution
Code AF
Malfunction of a humidifier system
View solution
Code AH
Malfunction of dust collector of air cleaner
View solution
Code AJ
Malfunction of capacity setting (Indoor unit PCB)
View solution
Code C1
Failure of transmission (between indoor unit PCB and sub PCB)
View solution
Code C4
Malfunction of liquid pipe thermistor for heat exchanger
View solution
Code C5
Malfunction of gas pipe thermistor for heat exchanger
View solution
Code C6
Malfunction of fan motor sensor or fan control driver
View solution
Code C7
Front panel driving motor fault
View solution
Code C9
Malfunction of suction air thermistor
View solution
Code CA
Malfunction of discharge air thermistor
View solution
Code CC
Malfunction of humidity sensor system
View solution
Code CJ
Room temperature thermistor in remote controller abnormality
View solution
Code E0
Protection devices activated (unified)
View solution
Code E1
Defective outdoor unit PCB
View solution
Code E3
Actuation of high pressure switch (HPS)
View solution
Code E4
Actuation of low pressure switch (LPS)
View solution
Code E5
Inverter compressor motor or overheat
View solution
Code E6
STD compressor motor overcurrent/lock
View solution
Code E7
Malfunction of outdoor unit fan motor system
View solution
Code E8
Overcurrent of inverter compressor
View solution
Code E9
Malfunction of electronic expansion valve coil
View solution
Code EA
Malfunction of four way valve or cool/heat switchin
View solution
Code EC
Malfunction of entering water temperature
View solution
Code F3
Malfunction of discharge pipe temperature
View solution
Code F6
Abnormal high pressure or refrigerant overcharged
View solution
Code H0
Malfunction of sensor system of compressor
View solution
Code H1
Malfunction of room temperature sensor or humidifier unit damper
View solution
Code H3
Malfunction of high pressure switch (HPS)
View solution
Code H4
Malfunction of low pressure switch (LPS)
View solution
Code H5
Malfunction of compressor motor overload thermistor
View solution
Code H6
Malfunction of position detection sensor
View solution
Code H7
Malfunction of outdoor unit fan motor signal
View solution
Code H8
Malfunction of compressor input (CT) system
View solution
Code H9
Malfunction of outdoor air thermistor
View solution
Code HC
Malfunction of (hot) water temperature thermistor
View solution
Code HF
Alarm in thermal storage unit or storage controller
View solution
Code HJ
Malfunction of thermal storage tank water level
View solution
Code J1
Malfunction of pressure sensor
View solution
Code J2
Malfunction of current sensor of compressor
View solution
Code J3
Malfunction of discharge pipe thermistor
View solution
Code J4
Malfunction of low pressure equivalent saturated temperature sensor system
View solution
Code J5
Malfunction of suction pipe thermistor
View solution
Code J6
Malfunction of heat exchanger thermistor
View solution
Code J7
Malfunction of thermistor (Refrigerant circuit)
View solution
Code J8
Malfunction of thermistor (Refrigerant circuit)
View solution
Code J9
Malfunction of thermistor (Refrigerant circuit)
View solution
Code JA
Malfunction of high pressure sensor
View solution
Code JC
Malfunction of low pressure sensor
View solution
Code JE
Malfunction of oil pressure sensor or sub-tank thermistor
View solution
Code JF
Malfunction of oil level sensor or heating heat exchanger thermistor
View solution
Code L0
Malfunction of inverter system
View solution
Code L1
Malfunction of inverter PCB
View solution
Code L3
El.compo. box temperature rise
View solution
Code L4
Malfunction of inverter radiation fin temperature rise
View solution
Code L5
nverter instantaneous overcurrent (DC output)
View solution
Code L6
Inverter instantaneous overcurrent (AC output)
View solution
Code L8
Malfunction of overcurrent inverter compressor
View solution
Code L9
Malfunction of inverter compressor startup error (Stall prevention)
View solution
Code LA
Malfunction of power transistor
View solution
Code LC
Malfunction of transmission between control and inverter PCB
View solution
Code M1
Malfunction of central remote controller PCB
View solution
Code M8
Malfunction of transmission between optional controllers for centralized control
View solution
Code MA
Improper combination of optional controllers for centralized control
View solution
Code MC
Address duplication, improper setting
View solution
Code P0
Shortage of refrigerant amount (thermal storage unit)
View solution
Code P1
Power voltage imbalance or inverter PCB
View solution
Code P2
Automatic refrigerant charge operation stop
View solution
Code P3
Malfunction of thermistor in switch box
View solution
Code P4
Malfunction of radiation fin temperature sensor
View solution
Code P8
Heat exchanger freezing protection during automatic refrigerant charging
View solution
Code P9
Malfunction of fan motor (humidifier unit)
View solution
Code PA
Refrigerant cylinder during automatic refrigerant charging
View solution
Code PC
Refrigerant cylinder during automatic refrigerant charging
View solution
Code PE
Automatic refrigerant charge operation nearly completed
View solution
Code PH
Refrigerant cylinder during automatic refrigerant charging
View solution
Code PJ
Malfunction of capacity setting (Outdoor unit PCB)
View solution
Code U0
Shortage of refrigeran
View solution
Code U1
Reverse phase, open phase
View solution
Code U2
Malfunction of power supply or instantaneous power failure
View solution
Code U3
Check operation not executed or transmission error
View solution
Code U4
Malfunction of transmission between indoor and outdoor unit
View solution
Code U5
Malfunction of transmission between indoor unit and remote controller
View solution
Code U6
Malfunction of transmission between indoor units
View solution
Code U7
Malfunction of transmission between outdoor units or outdoor storage unit
View solution
Code U8
Malfunction of transmission between remote controllers
View solution
Code U9
Malfunction of transmission (other system)
View solution
Code UA
Defect of indoor/outdoor power supply
View solution
Code UC
Malfunction of setting of centralized control equipment address
View solution
Code UE
Malfunction of transmission between indoor unit and centralized control equipment
View solution
Code UF
System is not set yet
View solution
Code UH
Malfunction of system
View solution
Code UJ
Malfunction of transmission (accessory device)
View solution
Code 60
External protection device activated (Heat reclaim ventilator)
View solution
Code 64
Malfunction of indoor air thermistor (Heat reclaim ventilator)
View solution
Code 65
Malfunction of outdoor air thermistor (Heat reclaim ventilator)
View solution
Code 6A
Malfunction of damper system (Heat reclaim ventilator)
View solution
Code 70
System No. 2 Compressor overheat
View solution
Code 71
System No. 2 Compressor overcurrent
View solution
Code 72
System No. 2 Fan motor overcurrent
View solution
Code 73
System No. 2 Actuation of high pressure switch (HPS)
View solution
Code 74
System No. 2 Actuation of low pressure switch (LPS)
View solution
Code 75
System No. 2 Malfunction of low pressure sensor
View solution
Code 76
System No. 2 Malfunction of high pressure sensor
View solution
Code 77
System No. 1 Malfunction of fan inter lock
View solution
Code 78
System No. 2 Malfunction of fan inter lock
View solution
Code 7A
System No. 2 Malfunction of compressor current sensor
View solution
Code 7C
System No. 2 Malfunction of pump inter lock
View solution
Code 80
Malfunction of entering water temperature thermistor
View solution
Code 81
Malfunction of leaving water temperature thermistor or drain pipe heater
View solution
Code 82
System No. 1 Malfunction of refrigerant thermistor
View solution
Code 83
System No. 2 Malfunction of refrigerant thermistor
View solution
Code 84
System No. 1 Malfunction of heat exchanger thermistor
View solution
Code 85
System No. 2 Malfunction of heat exchanger thermistor
View solution
Code 86
System No. 1 Malfunction of discharge pipe thermistor
View solution
Code 88
System No. 2 Malfunction of discharge pipe temperature
View solution
Code 89
Malfunction of brazed-plate heat exchanger freezing
View solution
Code 8A
System No. 2 Malfunction of leaving water temperature thermistor
View solution
Code 8E
System No. 1 Malfunction of suction pipe thermistor 1 for heating
View solution
Code 8F
System No. 1 Malfunction of suction pipe thermistor 2 for heating
View solution
Code 8H
Abnormal hot water high temperature
View solution
Code 90
Abnormal chilled water quantity or abnormal AXP
View solution
Code 91
System No. 2 Malfunction of electronic expansion valve
View solution
Code 92
System No. 2 Malfunction of suction pipe thermistor
View solution
Code 94
Malfunction of transmission (between heat reclaim ventilator and fan unit)
View solution
Code 95
System No. 1 Malfunction of inverter system
View solution
Code 96
System No. 2 Malfunction of inverter system
View solution
Code 97
Malfunction of thermal storage unit
View solution
Code 98
Malfunction of thermal storage brine pump
View solution
Code 99
Malfunction of thermal storage brine tank
View solution