代碼 PS5018 / BG5018 / SR5018: POLYGON SPINDLE SPEED ERROR
問題描述與安全警告
Fanuc 0i-D / 0i Mate-D Alarm List 觸發了嚴重的 POLYGON SPINDLE SPEED ERROR 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Section: CNC alarm list Alarm group: Program/operation, background edit, communication (PS/BG/SR common alarm number) Original alarm number: 5018 In G51.2 mode, the speed of the spindle or polygon synchronous axis either exceeds the clamp value or is too small. The specified rotation speed ratio thus cannot be maintained. For polygon turning between spindles: More information as to why this alarm occurred is indicated in DGN No. 471. An invalid value is set in parameter No. 7310, which specifies
Source: Fanuc B-64305EN/03 Appendix A Alarm List
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Fanuc 0i-D / 0i Mate-D Alarm List 警報
由 Fanuc 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 0i-D / 0i Mate-D Alarm List 出現類似 PS5018 / BG5018 / SR5018 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。