代碼 SPERR30: Serial spindle diagnosis indication 30
問題描述與安全警告
Fanuc 0i-D / 0i Mate-D Alarm List 觸發了嚴重的 Serial spindle diagnosis indication 30 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Section: Serial spindle diagnosis/error code Diagnosis indication: 30 The magnetic pole has not been detected, but a In the magnetic pole undetected state (EPFIXA command is input. = 0), the motor cannot be driven even when a command is input. Input a command in the magnetic pole detected state (EPFIXA = 1). When EPFSTR is set to 1, any command is ignored and this error is displayed even in the magnetic pole detected state. After the completion of magnetic pole detection, set EPFSTR to 0.
Source: Fanuc B-64305EN/03 Appendix A Alarm List
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Fanuc 0i-D / 0i Mate-D Alarm List 警報
由 Fanuc 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 0i-D / 0i Mate-D Alarm List 出現類似 SPERR30 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code SPERR30.
Need a searchable reference for more Fanuc 0i-D / 0i Mate-D Alarm List manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.