代码 FAT16: using another PC. (It cannot

问题描述与安全警告

Fanuc 30i/31i/32i CNC 触发了严重的 using another PC. (It cannot 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

be recognized if formatted in FAT32.) The memory card cannot be formatted. UNSUPPORTED MEMORYCARD Replace the memory card with another one. This memory card is not supported. CAN NOT DELETE FILE Check the attributes of the file. An error occurred when a file was deleted from the memory card. MEMORYCARD BATTERY ALARM Replace the battery of the memory card. The battery of the memory card has become weak. THIS FILE NAME IS ALREADY USED Change the file name to another one. T he file name is already used. MEMORYCARD ACCESS ERROR Replace the memory card with another one. The memory card cannot be accessed. DIFFERENCE FOUND File com parison detected a mismatch. MEMORY CARD IS LOCKED BY OTHER FUNCTION Wait until the PMC user completes processing, then retry. Another PMC user is using the memory card. MEMORY CARD HEADER ROM DATA ID IS ILLEGAL This file cannot be read. Check the type of the file. An attempt was made to read a file, but its ROM data ID was illegal. FILE NUMBER CAN NOT SELECTED If the file does not exist, the key entry is invalid. If this error occurs even when the cursor is placed at a file name, contact the FANUC service center. The file number cannot be selected. THE FILE NUMBER DOES NOT EXIST Check the total number of files on the list screen. The entered file number is not present. The entered number exceeds the total number of files. FILE NUMBER IS RESTRICTED TO "128" Enter a numeric value not exceeding 128. A value up to 128 can be entered as the file number. MEMORY CARD IS USED BY OTHER FUNCTION Retry after terminating the other function that is cu rrently using the memory card. Some other function is currently using the memory card. MEMORY CARD IS WRITE PROTECTED Cancel the write protection of the memory card, or use another memory card that is not write protected. The memory card is write protected. UNSUPPORTED MEMORY CARD Use another memory card. This is an unsupported type of memory card. COULD NOT DELETE FILE C heck the read/write permission attribute of the file. The file cannot be deleted. TRACE FILE NUMBER IS OVER Delete unnecessary old trace result file or files. No more trace result file can be created because the maximum trace result file number (file extension) has been reached. UNSUPPORTED TRACE SETTING FILE This file cannot be handled. Set data in the TRACE SETING screen. An attempt was made to read a trace setting file that could not be handled. INVALID SETTING VALUE (LINE n) Output the trance setting file again. Alternatively, set data in the TRACE SETING screen. An invalid setting is found. The file may be damaged. SAMPLING TIME/FRAME WAS ADJUSTED Check the data on the TRACE SETING screen. The values are adjusted according to the read data. (This is warning.) UNKNOWN SETTING WAS SKIPPED(LINE n) Check the read trace data. An unk nown trace setting item is found and ignored. (This is warning.) INVALID SAMPLING ADDRESS WAS FOUND Check the read trace data. An invalid sampling address is found. (This is warning.) TOO MANY SAMPLING ADDRESSES Check the read trace data. T he number of sampling addresses exceeds the upper limit. (This is warning.) INTERNAL ERROR (xxxxxxxxxx) C ontact the FANUC service center, and report the displayed message correctly. An error due to an internal factor occurred. Details on the error are displayed in parentheses. FILE NAME CONTAINS RESERVED WORD. Correct file name. “FOR FANUC” cannot be used in the top of t he file name. USB MEMORY HAS BEEN REMOVED Insert the USB memory, then execute input/out put operation again. A USB memory is removed while it is being accessed. USB MEMORY IS NOT READY. Check whether a USB memory is inserted. No USB memory is inserted. USB MEMORY IS USED BY OTHER FUNCTION. Terminate another function that is using the USB memory, then perform operation again. The USB memory is being used by another function. THIS FILE NAME IS ALREADY USED. OVERWRITE IT? Follow the message, and overwrite the file or specif y another file name to write data. An existing file name is specified as the write destination. FILE NOT FOUND Check the file name or number on the file list screen. The specified file is not found. USB MEMORY IS FULL. Delete any unnecessary files and allocate a required capacity. The USB memory is full. FILE IS READ-ONLY. Specify anot her file or check the file attribute and delete the read-only attribute. The specified file is read-only. USB MEMORY IS NOT FORMATTED Replace the USB memory with another one. The inserted USB memory cannot be recognized. FILE NAME IS INVALID. Correct the file name. An invalid character is found in a file name. DIFFERENCE FOUND File comparison detected a mismatch. THE FILE NUMBER DOES NOT EXIST Check the total number of files on the list screen. The entered file number is not found. The entered number is greater than the total number of files. FILE NUMBER IS RESTRICTED TO "128" Enter a numeric value not greater than 128. A value up to 128 can be entered as the file number. FOLDER CANNOT BE SPECIFIED. <1> The specified number indicates a folder. Enter an appropriate number. <2> No folder can be selected in the file list screen. <1> The specified number indicates a folder. <2> An attempt was made to select a folder in the file list screen. THIS FILE CANNOT BE SPECIFIED. <1> The file name corresponding to the specified file number consists of more than 32 characters. Enter an appropriate number. <2> No file having a file name consisting of more than 32 characters can be selected in the file list screen. <1> The file name corresponding to the specified file number consists of more than 32 characters. <2> An attempt was made to select a file having a file name consisting of more than 32 characters. USB HARDWARE ERROR (xxxxxxxxxx) Replace the USB memory with another one. If this error still occurs after replacement, contact the FANUC service center, and report the displayed message correctly. This error occurs due to a USB hardware failure. An error code is indicated in parentheses. INTERNAL ERROR (xxxxxxxxxx) Contact us, and report the displayed message correctly. This error occurs due to an internal factor. An error code is indicated in parentheses. NOT IN EMG STOP MODE Place the system in the emergency stop state. The system is not in the emergency stop state. INVALID LADDER PROGRAM Check the program. The transfer program is illegal. DIFFERENCE FOUND A file com parison detected a mismatch. FLASH ROM IS LOCKED BY OTHER FUNCTION Wait until the PMC user completes processing, then retry. Another PMC user is using the flash ROM. FLASH ROM HEADER ROM DATA ID IS ILLEGAL This file cannot be read. Check the type of the file. An attempt was made to read a file, but its ROM data ID was illegal. FLASH ROM IS USED BY OTHER FUNCTION This file cannot be read. Check the type of the file. The ROM data ID of the file you attempted to read is invalid. INTERNAL ERROR (xxxxxxxxxx) C ontact the FANUC service center, and report the displayed message correctly. An error due to an internal factor occurred. Details on the error are displayed in parentheses. ILLEGAL PMC PARAMETER FORMAT Specify a file of the PMC parameter format. Also, check the specified file to see whether its content is not disrupted. The specified file is not of the PMC parameter format. ILLEGAL HANDY FILE FORMAT Specif y a file of the handy file format. Also, check the specified file to see whether its content is not disrupted. The specified file is not of the handy file format. UNKNOWN FILE FORMAT Specify file of recognizable format such as PMC parameter format, or check the contents of the file. Can not recognize the format of specified file. FILE NAME OR FILE NUMBER IS REQUIRED Specify file name or file number for the operation. Need file name or file number to identify file to read, compare, or delete. COMMUNICATION TIMEOUT Check the communication parameters such as baud rate, and retry to communicate. Communication with the I/O device has been timeout. I/O DEVICE IS NOT ATTACHED OR IN ERROR STATUS Check the power of I/O device is ON. Check the I/O device is connected. Check the cable that connects I/O device with PMC is correct one. If some error has occurred in I/O device, solve it. Any I/O device is not connected, or some error has occurred in it. RECEIVED BAD DATA: CHECK THE COMMUNICATION PARAMETERS Check the PMC's communication parameters such as baud rate match the ones of I/O device. Invalid data has been received. RECEIVED DATA HAS OVERRUN Check the communication parameters about flow control. Too many data have received at once. OTHERS FUNCTION IS USING THIS CHANNEL Use the other channel, or stop the function. Others function is using this channel. BAD COMMUNICATION PARAMETER Check the communication parameters such as baud rate. Setting parameters of communication are not correct. OTHER FUNCTION IS USING I/O FUNCTION Wait until function that using I/O function do finish, or stop the function. Another function such as FANUC LADDER-III is using I/O function. UNKNOWN HANDY FILE FORMAT DATA Check the file. The received dat a is not a program of the PMC system or is a program of some other incompatible type. ILLEGAL BAUD RATE SETTING Set a valid baud rate. The set baud rate is invalid. ILLEGAL CHANNEL NUMBER Set a valid channel number. The set channel number is invalid. ILLEGAL PARITY BIT SETTING Set a valid par ity bit. The set parity bit is invalid. ILLEGAL STOP BIT SETTING Set a valid stop bit. The set stop bit is invalid. ILLEGAL WRITE CODE SETTING Set a valid output code. The set output code is invalid. SEQUENCE PROGRAM IS IN USE BY ONLINE FUNCTION Wait until On-line function, do finish the using I/O function. In general, both of I/O function and On-line function should not be used at the same time. Can not input/output of sequence program, because On-line function is using sequence program. ERROR OCCURS IN LADDER PROGRAM Check the PMC alarm screen and correct the indicated program error accordingly. Data cannot be output because there is an error in the ladder program. UNKNOWN DATA TYPE Check the file. The PMC type of the input data is unknown. MUST BE IN EMERGENCY STOP Set the NC to the emergency stop state. The NC is not in the emergency stop state when the PMC par ameter is read. PWE MUST BE ON Set PWE to 1 on the NC setting screen. PWE on the NC setting screen is 0 during reading from the PMC parameter. MUST BE IN EDIT MODE Set the NC to the EDIT mode. The NC is not in the EDIT mode during writing to the PMC parameter. THIS FUNCTION IS NOT ALLOWED Release the protection by the programmer protection function or 8-level protection function. Protection is made by the programmer protection function or 8-level protection function. PMC PARAMETER IS LOCKED BY OTHER FUNCTION Retry after terminating the other function that is cu rrently using the PMC parameter. The PMC parameter is currently used by some other function and cannot be referenced by this function. THIS DEVICE IS USED BY OTHER FUNCTION Retry after terminating the other function that is cu rrently using the specified device. The specified device is currently used by some other function and cannot be used by this function. PMC PARAMETER IS PROTECTED BY OTHER FUNCTION Retry after terminating the other function that is cu rrently using the PMC parameter. The PMC parameter is currently used by some other function and cannot be changed by this function. LADDER TYPE UNMATCH Specify a program of a valid ty pe. The specified program is of a different type and cannot be read. TOO LARGE SEQUENCE PROGRAM Check the file. Or, change to a step number option that allows you to set a larger program size. The ladder program is too large to read. SEQUENCE PROGRAM IS USED BY OTHER FUNCTION Retry after terminating the other function that is currently displaying the ladder program. The ladder program is currently used by some other function and cannot be referenced by this function. INVALID I/O CONFIGURATION DATA Read correct I/O configuration file. In valid I/O configuration data was read and any of the following operations was performed: - Writing it to the memory card - Comparing it with a memory card file USB - Writing it to flash ROM -Comparing it with flash ROM TOO LARGE I/O CONFIGURATION DATA Check the I/O configuration file. The I/O configuration file is too large to read. I/O CONFIGURATION DATA IS USED BY OTHER FUNCTION Terminate another function that is using the I/O confi guration data, then execute operation again. I/O configuration data is being used by another function (such as FANUC LADDER-III).

Source: Fanuc Series 30i/31i/32i-A Maintenance Manual, Appendix A Alarm List — PMC alarms (B-64485EN/01)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Fanuc 30i/31i/32i CNC 警报

由 Fanuc 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 30i/31i/32i CNC 出现类似 FAT16 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 85 Fanuc 30i/31i/32i CNC 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code FAT16.

Manual conversion service

Need a searchable reference for more Fanuc 30i/31i/32i CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相关的 Fanuc 30i/31i/32i CNC 代码