El Fanuc R-30i Series Robot Controller ha desencadenado una alarma crítica Calibration data is not selected.. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.
Pasos oficiales de solución de problemas
Cause: Calibration data is not selected. Remedy: Select calibration data. CVIS-516: The 2-D Barcode reader does not support QR Code Model 1. Cause: The 2-D Barcode is QR Code Model 1. This code is is old and is not supported. Remedy: None. CVIS-522: Failed to detect motion. Cause: Motion of axis failed to be detected. Remedy: Check measuring group number is the same as selected group number on UIF. Check measuring axis number is the same as selected axis number on UIF. CVIS-523: Failed to align to ref. pos. Cause: Target mark can't be aligned to reference position. Remedy: Check measuring group number is the same as selected group number on UIF. Check measuring axis number is the same as selected axis number on UIF. Check attachment of measuring target mark again. CVIS-524: Robot position is invalid. Cause: Robot position is invalid. Remedy: Pease don't jog robot or execute other programs during step data measurement. CVIS-525: Master image is not trained. Cause: Master image is not trained. Remedy: Train master image first. CVIS-526: Wrong master image size. Cause: The size of image to add does not coincide with the size of master image. Remedy: Either capture or load an image with the size of master image, or clear the master image first. CVIS-527: Master image reference pose is not set. Cause: Window Shift Tool is inserted before Surface Flaw Inspection Tool. Remedy: Train master image for static removal again. CVIS-528: Shading coefficients are not set. Cause: Shading coefficients are not set. Remedy: Train master image for shading removal first. CVIS-529: Shading coefficients cannot be calculated. Cause: Not enough pixels are available to calculate the shading coefficients. Remedy: Re-edit the run-time mask for shading background removal and reduce the area to mask. CVIS-530: Image is not suitable for teaching shading removal. Cause: The image is not suitable for teaching shading removal. Remedy: Use another image preprocess, or mask the pixels that have irrelevant grayscale change. 4.4 D 4.4.1 DICT Alarm Code
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Acerca de las alarmas de Fanuc R-30i Series Robot Controller
Los controladores industriales construidos por Fanuc están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un R-30i Series Robot Controller arroja un código de error como CVIS-508, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.
Lista completa de alarmas: 6553 Fanuc R-30i Series Robot Controller códigos.
Have a better solution?
Help the industrial community by sharing your repair experience for code CVIS-508.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026