代碼 FRCE-153: F/S SLC2 frmaing error (F:%d^1)
問題描述與安全警告
Fanuc R-30i Series Robot Controller 觸發了嚴重的 F/S SLC2 frmaing error (F:%d^1) 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Cause: Communication with the sensor board failed. Remedy: 1. Move the robot to a safe pose. 2. Turn the controller OFF, then ON again. If this alarm occurs again, go to the next step. 3. Remove any sources of noise in the sensor system. Turn the controller OFF, then ON again. If this alarm occurs again, go to the next step. 4. Make sure that the shield lines of the cables are connected to the frame ground. Make sure that the peeled part of the cable in the cabinet is properly connected to the earth plate. If this alarm occurs again, go to the next step. 5. This alarm occurs when the number of errors exceeds the serial allowed number or the total allowed number. Therefore, this alarm can be avoided by increasing the serial allowed number (system var $CCS_GRP.$ALARMSERAL) or the total allowed number (system var $CCS_GRP.$ALARMTOTAL). If the alarm still occurs after increasing these numbers, go to the next step. 6. Replace the sensor board.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Fanuc R-30i Series Robot Controller 警報
由 Fanuc 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 R-30i Series Robot Controller 出現類似 FRCE-153 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code FRCE-153.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026