代碼 SDTL-072: Torque Limit disabled
問題描述與安全警告
Fanuc R-30i Series Robot Controller 觸發了嚴重的 Torque Limit disabled 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Cause: Torque limit function of specified group or axis is disabled. Remedy: See the Chapter, “Torque Limit Function” of R-30iA/R-30iA Mate CONTROLLER OPERATOR’S MANUAL and the Subsection 8.3.1.1 ” How to Set up Torque Limit” of R-30iA/R-30iA Mate System Design Tool OPERATOR’S MANUAL (B-83174EN). Enable the torque limit of specified group and axis.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Fanuc R-30i Series Robot Controller 警報
由 Fanuc 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 R-30i Series Robot Controller 出現類似 SDTL-072 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。