FaultResolve
Volver al directorio de búsqueda
Search this section

Search Fanuc R-30i Series Robot Controller

Search other Fanuc R-30i Series Robot Controller alarms without going back to the model list.

Search all database

Código SVGN-020: Pressure shortage%d: Gun%d

Descripción del problema y advertencia de seguridad

El Fanuc R-30i Series Robot Controller ha desencadenado una alarma crítica Pressure shortage%d: Gun%d. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.

Pasos oficiales de solución de problemas

Cause: The SPOT, PRESS_MOTN or TIPDRESS, instruction failed because gun closure was not detected(1) or gun pressure was unstable(2). The number after pressure shortage (1 or 2) identifies the failure type. Scan the list below for the cause that most nearly matches the condition at hand, then refer to the remedy for that cause. Shortage 1) The instruction completed - gun tip moved to the pushing depth position - without torque increasing to the gun close detection value (1/2 Std Overtorque Value). z 1A) If gun moved to current close axis limit without achieving pressure, then axis limit is too small. If stroke limit is decreased, push depth is too small to achieve pressure. Push depth status can be confirmed SVGN-158 as cause code. SVGN-158 shows current available push depth and maximum push depth. When available push depth is too smaller than max push depth, it shows current stroke limit is too small than one of the new tip. z 1B) Pushing depth parameter in pressure schedule is not large enough to overcome gun bending at target pressure plus tip wear amount since last measurement. z 1C) Part thickness parameter (Thk from SVGN-158) is much larger than actual part thickness z 1D) Gun zero master position is incorrect (if tips are worn and user chooses to not use tip wear comp, then start with 1B) z 1E) Gun close detection torque may be excessive (or larger than Max Motor torque) due to a large restriction in gun mechanism. Shortage 2) The torque for pressuring varied from the target value. There are (2) likely causes: z 2A) Target pressure is at very low or high end of gun operating range (tips are likely touching part) z 2B) Friction in gun mechanism has increased considerably since gun was autotuned (tips are likely NOT touching part) Remedy: Shortage 1) z 1A) When tip wear compensation is used, close axis limit is adjusted to avoid over-stroking gun (ClosLim becomes smaller than StdLim when caps are worn). To extend axis limit, change tips, then run tip wear comp update program when using tip wear comp. Next, check the original close limit (StdLim) setting on servo gun setup screen and adjust if not correct. z 1B) Increase pushing depth in pressure schedule (set $sgsyscfg.$sho_pshdpth=TRUE to see pushing depth parameter) z 1C) Reduce part thickness in the pressure schedule so it is closer to actual part thickness. z 1D) If using tip wear compensation, re-master the gun by running the tip wear compensation update program. Otherwise, refer to 1B or re-master the gun with new tips from the gun master screen. z 1E) Adjust the gun mechanism to relieve the restriction. Re-tune the gun (autotune) and calibrate pressure after adjustment. Shortage 2) z 2A) Re-tune the gun (autotune) then confirm pressure calibration. If problem persists, or if the alarm occurs during tip wear measurement, autotune with Initial Filter set to a value between 10-30. To see Initial Filter item, set $sgsyscfg.$sho_atn_cfg=TRUE then press enter on Auto Tune item from Gun Setup Utility before tuning. z 2B) Re-tune the gun (autotune) to adjust the gun close detection limit, then confirm pressure calibration. If required, adjust the gun mechanism to relieve the cause of friction increase.

Source: FANUC Robot R-30iA Alarm Code List Operator's Manual

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

Acerca de las alarmas de Fanuc R-30i Series Robot Controller

Los controladores industriales construidos por Fanuc están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un R-30i Series Robot Controller arroja un código de error como SVGN-020, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.

Lista completa de alarmas: 6553 Fanuc R-30i Series Robot Controller códigos.

Have a better solution?

Help the industrial community by sharing your repair experience for code SVGN-020.

Manual conversion service

Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Códigos relacionados de Fanuc R-30i Series Robot Controller