Código SVGN-273: Det was irregular stop. R:%d, P:%d
Descripción del problema y advertencia de seguridad
El Fanuc R-30i Series Robot Controller ha desencadenado una alarma crítica Det was irregular stop. R:%d, P:%d. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.
Pasos oficiales de solución de problemas
Cause: A gun tip was contacted an upper panel surface on a free running section before search motion. Remedy: R:1 means that error occurred during upper panel detection. Confirm that gun tip has enough clearance from upper panel surface at start position. If distance between the tip and the panel is too short, confirm that: 1. no obstruction exists between guntip and panel. If the above item is OK, confirm that: 1. nominal thickness in pressure schedule is correct. 2. OverThickness tolerance (on gun teach setup screen) is large enough. If the above items are OK, confirm that: 1. Max allowable Pos error (on gun teach setup screen) is large enough. If the above item is NG, the position error is made less than maximum allowable position error in the following ways. 1. Touch up correct position using jog or point touchup(not program touchup). 2. Increase maximum allowable position error on gun teach setup screen. R:3 means that error occurred during lower panel detection. Confirm that robot tip has enough clearance from panel surface at start position and that there is no obstacle between the panel and the robot tip at start position. If distance between the tip and the panel is too short, increase start distance(SD) for robot tip and/or lower panel detection distance. Refer to Chapter “20.6 LOWER PANEL DETECTION DISTANCE CLAMP” or “20.13 SPTCH_RSD INSTRUCTION” in operator’s manual for Servo Gun Function for more information about the lower panel detection distance. Retry spot program touchup. If this problem persists after taking the above actions, perform the following actions: 1. Acquire the diagnostic data. See the procedure for diagnostic data collection at Chapter “20.19 Troubleshooting” in operator’s manual for Servo Gun Function.. 2. Contact your local FANUC representative. Note: This alarm is posted when the time to execute phases2,3 take longer than anticipated, during upper1 detection and lower detection. R: Request number. R:1 is upper1 detection. R:3 is lower detection. P: Phase number. P:2 is phase of acceleration. P3: is phase to collect data to calculate threshold. If the tip touch panel during above phase, this alarm is posted. Please check whether the tip touch panel or the gun is closed(or grabbed panel) at position of search start.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Acerca de las alarmas de Fanuc R-30i Series Robot Controller
Los controladores industriales construidos por Fanuc están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un R-30i Series Robot Controller arroja un código de error como SVGN-273, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.
Lista completa de alarmas: 6553 Fanuc R-30i Series Robot Controller códigos.
Have a better solution?
Help the industrial community by sharing your repair experience for code SVGN-273.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026