コード SYST-223: Image backup failed(0x%x)
問題の説明と安全警告
Fanuc R-30i Series Robot Controller は重大な Image backup failed(0x%x) アラームをトリガーしました。製造サイクル中に機器への二次的損傷や部品の破損を防ぐために、資格のあるオペレーターまたはメンテナンス技術者による直ちの対応が必要です。電気キャビネットにアクセスする前に、必ず標準の安全およびLOTO手順が遵守されていることを確認してください。
公式トラブルシューティング手順
Cause: Image backup failed. Remedy: 0x%x shows the cause of the failure. Find the definition in the list below. Remove the cause of the failure and try the backup again. z 0x%x Cause and remedy 0x1 This isn't used. 0x2 Memory allocation failed. Call your local FANUC representative. z 0x3 Information in FROM cannot be acquired. Call your local FANUC representative. z 0x4 Make sure there is enough free space on the MC. Make sure a FLASH ATA card is inserted in the MC card slot. z 0x5 Controller could not open FROM***.IMG. Destination device might be broken. z 0x6 Controller could not read FROM. FROM module or main board FROM might be broken. z 0x7 Controller could not write data to FROM***.IMG. Destination device might be broken. z 0x8 Controller could not close FROM***.IMG. The following are possible causes: z There are already backup files on the destination device and they are write-protected. z MC was removed during backup. z Communication was disconnected during backup to TFTP server. z TFTP server is not running. z 0x9 Make sure there is enough free space on MC. Make sure FLASH ATA card is inserted to MC card slot. z 0xa Controller cannot open SRAM***.IMG. Destination device might be broken. z 0xb Controller could not write data to SRAM***.IMG. Destination device might be broken. z 0xc Controller could not close SRAM***.IMG. The following are possible causes: z There are already backup files on the destination device and they are write-protected. z MC was removed during backup. z Communication was disconnected during backup to TFTP server. z TFTP server is not running. z 0xd File for internal use may be broken. Try the backup again. z 0xe File for internal use may be broken. Try the backup again. z 0xf After power was cycled by image backup function, a backup file was found on the MC. This happens if power is turned off during automatic image backup. Retry backup from file screen again. z 0x20 Initialization of network failed. Confirm wiring and BOOTP server is running.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Fanuc R-30i Series Robot Controller のアラームについて
Fanuc によって構築された産業用コントローラーは、内部回路と機械的リンケージを保護するための広範な診断システムで設計されています。R-30i Series Robot Controller が SYST-223 のようなエラーコードをスローする場合、通常、指令値と実際のセンサーフィードバック間の不一致を示します。
Have a better solution?
Help the industrial community by sharing your repair experience for code SYST-223.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026