代碼 SYST-223: Image backup failed(0x%x)
問題描述與安全警告
Fanuc R-30i Series Robot Controller 觸發了嚴重的 Image backup failed(0x%x) 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Cause: Image backup failed. Remedy: 0x%x shows the cause of the failure. Find the definition in the list below. Remove the cause of the failure and try the backup again. z 0x%x Cause and remedy 0x1 This isn't used. 0x2 Memory allocation failed. Call your local FANUC representative. z 0x3 Information in FROM cannot be acquired. Call your local FANUC representative. z 0x4 Make sure there is enough free space on the MC. Make sure a FLASH ATA card is inserted in the MC card slot. z 0x5 Controller could not open FROM***.IMG. Destination device might be broken. z 0x6 Controller could not read FROM. FROM module or main board FROM might be broken. z 0x7 Controller could not write data to FROM***.IMG. Destination device might be broken. z 0x8 Controller could not close FROM***.IMG. The following are possible causes: z There are already backup files on the destination device and they are write-protected. z MC was removed during backup. z Communication was disconnected during backup to TFTP server. z TFTP server is not running. z 0x9 Make sure there is enough free space on MC. Make sure FLASH ATA card is inserted to MC card slot. z 0xa Controller cannot open SRAM***.IMG. Destination device might be broken. z 0xb Controller could not write data to SRAM***.IMG. Destination device might be broken. z 0xc Controller could not close SRAM***.IMG. The following are possible causes: z There are already backup files on the destination device and they are write-protected. z MC was removed during backup. z Communication was disconnected during backup to TFTP server. z TFTP server is not running. z 0xd File for internal use may be broken. Try the backup again. z 0xe File for internal use may be broken. Try the backup again. z 0xf After power was cycled by image backup function, a backup file was found on the MC. This happens if power is turned off during automatic image backup. Retry backup from file screen again. z 0x20 Initialization of network failed. Confirm wiring and BOOTP server is running.
Source: FANUC Robot R-30iA Alarm Code List Operator's Manual
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Fanuc R-30i Series Robot Controller 警報
由 Fanuc 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 R-30i Series Robot Controller 出現類似 SYST-223 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code SYST-223.
Need a searchable reference for more Fanuc R-30i Series Robot Controller manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026