Fanuc R-30i Series Robot Controller
Fanuc R-30i Series Robot Controller Error Codes
Complete alarm and error code reference for the Fanuc R-30i Series Robot Controller. Browse all 6553 documented fault codes below, each linking to a detailed troubleshooting guide.
Search this section
Search Fanuc R-30i Series Robot Controller
Search all 6553 Fanuc R-30i Series Robot Controller codes without changing pages.
Complete Alarm List (Page 21 of 33)
Code PICK-021
The ID # of the robot unknown.
View solution Code PICK-022
Total util of all robots < 100
View solution Code PICK-023
No PickTool QMGR variable
View solution Code PICK-024
Not all Reference sysv exist
View solution Code PICK-025
Encoder not setup yet
View solution Code PICK-035
Invalid encoder number
View solution Code PICK-036
Invalid motion group
View solution Code PICK-037
Robot is not calibrated
View solution Code PICK-038
DIN port is ON
View solution Code PICK-039
Invalid $LNSCH number
View solution Code PICK-040
Not all positions are recorded
View solution Code PICK-041
Recorded points are too close
View solution Code PICK-042
$LNSCH has not been setup
View solution Code PICK-043
No duplicated update
View solution Code PICK-044
Please follow the steps
View solution Code PICK-045
Invalide reference position
View solution Code PICK-046
Set Track Frame first.
View solution Code PICK-100
Error opening %s.
View solution Code PICK-103
Invalid PickTool object id.
View solution Code PMON-001
Failed to notify PC Monitor
View solution Code PMON-002
Memory allocation failure
View solution Code PMON-003
Connect to PMON server failed
View solution Code PMON-004
PMON initialization failure
View solution Code PMON-005
PMON timer failure
View solution Code PMON-006
PMON task status read failed
View solution Code PMON-007
Lost connection to %s
View solution Code PMON-008
PMON curpos read failed
View solution Code PMON-009
PMON monitor not found
View solution Code PRIO-001
Illegal port type code
View solution Code PRIO-002
Illegal port number
View solution Code PRIO-003
No memory available
View solution Code PRIO-004
Too few ports on module
View solution Code PRIO-005
bad port number
View solution Code PRIO-006
bad port number
View solution Code PRIO-007
No match in SET_PORT_ASG de-assign
View solution Code PRIO-008
physical ports not found
View solution Code PRIO-009
number of ports invalid
View solution Code PRIO-010
bad physical port number
View solution Code PRIO-011
Assignment overlaps existing one
View solution Code PRIO-012
Bad board address
View solution Code PRIO-013
No analog input sequence for bd
View solution Code PRIO-014
Analog input sequnce too long
View solution Code PRIO-017
I/O point not simulated
View solution Code PRIO-020
I/O Link comm error %x, %x, %x, %x (hex)
View solution Code PRIO-021
Unknown I/O hardware
View solution Code PRIO-022
Too much I/O data on I/O link
View solution Code PRIO-023
No ports of this type
View solution Code PRIO-033
PLC interface init. fault %d
View solution Code PRIO-034
PLC interface general fault %d
View solution Code PRIO-035
PLC interface serial fault %d
View solution Code PRIO-037
Not supported for spec. port type
View solution Code PRIO-063
Bad I/O asg: rack %d slot %d
View solution Code PRIO-070
PLC interface option not loaded
View solution Code PRIO-072
Too many pulses active
View solution Code PRIO-076
PLC I/O hardware not installed
View solution Code PRIO-081
I/O is not initialized
View solution Code PRIO-083
Digital I/O is not recovered
View solution Code PRIO-089
PMC is not supported on this hardware
View solution Code PRIO-090
SNPX communication error
View solution Code PRIO-091
Op panel comm error(ch:%d) %x, %x (hex)
View solution Code PRIO-092
Force sensor comm error %x, %x (hex)
View solution Code PRIO-093
Fuse blown Rack:%d Slot:%d
View solution Code PRIO-094
Overload Rack:%d Slot:%d DO:%d-%d
View solution Code PRIO-095
Overload %s
View solution Code PRIO-096
SNPX Connection is full<%s>
View solution Code PRIO-097
SNPX time out<%s>
View solution Code PRIO-100
Model B comm fault %srack:%d slot:%d
View solution Code PRIO-102
Cycle power to restart PLC I/O
View solution Code PRIO-104
Device is off-line
View solution Code PRIO-106
Device with port is off-line
View solution Code PRIO-119
Too many DIGITAL I/O ports
View solution Code PRIO-121
Stop PMC program
View solution Code PRIO-125
SLC2 initialization error
View solution Code PRIO-126
No PMC program
View solution Code PRIO-127
PMC file load error
View solution Code PRIO-128
T,C,K and D data may be lost
View solution Code PRIO-129
SUB%d is not supported
View solution Code PRIO-130
PMC option is not installed
View solution Code PRIO-131
PMC file name error
View solution Code PRIO-132
PMC operation is locked
View solution Code PRIO-133
PMC program size is too big
View solution Code PRIO-134
Invalid PMC addr %s%d.%d
View solution Code PRIO-135
PMC address is not assigned
View solution Code PRIO-136
BYTE access to %s%d.%d
View solution Code PRIO-137
BIT access to %s%d.%d
View solution Code PRIO-138
%s%d is used in SUB%d
View solution Code PRIO-139
Invalid CNC addr %x.%x(hex)
View solution Code PRIO-140
Can't display all PMC errors
View solution Code PRIO-141
Invalid PMC program
View solution Code PRIO-142
Need E-STOP or CTRL start
View solution Code PRIO-143
Writting PMC program to ROM
View solution Code PRIO-144
Faild to run PMC program
View solution Code PRIO-145
Purging flash file, please wait
View solution Code PRIO-146
Flash file purge is completed
View solution Code PRIO-147
DIO config file too new
View solution Code PRIO-148
DIO config file too old
View solution Code PRIO-149
Invalid assignment recorded
View solution Code PRIO-150
CNET Card Init Error Bd %d
View solution Code PRIO-151
CNET Internal Error 0x%x
View solution Code PRIO-152
CNET Invalid Scan Config Bd %d
View solution Code PRIO-153
CNET Conn. Ownership Conflict
View solution Code PRIO-154
CNET Duplicate Mac ID Bd %d
View solution Code PRIO-155
CNET Network Error Bd %d
View solution Code PRIO-156
CNET Er %s Bd %d MAC %d
View solution Code PRIO-157
CNET Err Loading BIN file Bd %d
View solution Code PRIO-158
CNET File Not Found
View solution Code PRIO-159
CNET Cycle pwr to restart scan
View solution Code PRIO-160
CNET Connections Broken Bd %d
View solution Code PRIO-161
CNET Network Change Occuring
View solution Code PRIO-162
CNET Connections Restored Bd %d
View solution Code PRIO-163
CNET Network Change Complete
View solution Code PRIO-164
CNET Scan list modified Bd %d
View solution Code PRIO-165
CNET Connection Not Found
View solution Code PRIO-166
CNET Invalid Connection Type
View solution Code PRIO-167
CNET Vend ID/Prod. Code Mismatch
View solution Code PRIO-168
CNET Invalid Connection Size
View solution Code PRIO-169
CNET Device Not Configured
View solution Code PRIO-170
CNET Product Type Mismatch
View solution Code PRIO-171
CNET Maj/Min Revision Mismatch
View solution Code PRIO-172
CNET Target App Out of Conn.
View solution Code PRIO-173
CNET Needs Network Config.
View solution Code PRIO-174
CNET Connection Lost
View solution Code PRIO-175
CNET Bad Device State
View solution Code PRIO-176
CNET Connection Request Failed
View solution Code PRIO-177
CNET Invalid configuration
View solution Code PRIO-178
Blk scns lost; %d %d %d
View solution Code PRIO-179
Run scns lost; %d %d %d
View solution Code PRIO-180
CNET Sys Err %d %d 0x%x
View solution Code PRIO-181
CNET Conn. Req. Timeout
View solution Code PRIO-182
CNET CCO Change Aborted
View solution Code PRIO-183
Unknown port type name
View solution Code PRIO-184
CNET Connection Idle
View solution Code PRIO-185
CNET Config Er %d %d
View solution Code PRIO-186
CNET Invalid Header size
View solution Code PRIO-187
CNET Invalid Num of Slots
View solution Code PRIO-188
Sim. Skip output not defined
View solution Code PRIO-189
(%s^4, %d^5) WAIT will time out
View solution Code PRIO-191
AB-RIO Board Init Error
View solution Code PRIO-192
AB-RIO No Board Found
View solution Code PRIO-193
AB-RIO Failed to Load FW
View solution Code PRIO-194
AB-RIO Failed to Start FW
View solution Code PRIO-195
AB-RIO Failed to Clear Config
View solution Code PRIO-196
AB-RIO Config Error, Slot %d
View solution Code PRIO-197
AB-RIO Slot %d Idle
View solution Code PRIO-198
AB-RIO Slot %d in Test/Prog
View solution Code PRIO-200
FIPIO System Error %d
View solution Code PRIO-201
FIPIO PCB not installed
View solution Code PRIO-202
FIPIO PCB Abnormal
View solution Code PRIO-203
FIPIO Duplicate FIP Address
View solution Code PRIO-204
FIPIO Send Buffer Error
View solution Code PRIO-205
FIPIO Receive Buffer Error
View solution Code PRIO-206
FIPIO Physical Reset
View solution Code PRIO-207
FIPIO BadPrm; CMD %x,%x
View solution Code PRIO-208
FIPIO NRDY; CMD %d LNG %d
View solution Code PRIO-209
FIPIO Connection Broken
View solution Code PRIO-210
FIPIO Cnf/Adj not available
View solution Code PRIO-211
FIPIO Bad Cnf/Adj status
View solution Code PRIO-212
FIPIO Connection TimeOut
View solution Code PRIO-213
FIPIO Connection Established
View solution Code PRIO-214
FIPIO Connection Recovered
View solution Code PRIO-220
EGD Producer name/IP not init
View solution Code PRIO-221
EGD Consumer size misconfigured
View solution Code PRIO-222
EGD Consumer init failed
View solution Code PRIO-223
EGD Producer socket error
View solution Code PRIO-224
EGD System Error
View solution Code PRIO-225
EGD Consumer timeout - Id:%d
View solution Code PRIO-226
EGD Consumer socket create error
View solution Code PRIO-227
EGD Consumer socket bind error
View solution Code PRIO-228
EGD System error - Code:%x
View solution Code PRIO-230
EtherNet/IP Adapter Error (%d)
View solution Code PRIO-231
EtherNet/IP Adapter Idle
View solution Code PRIO-232
EtherNet/IP Not Initialized
View solution Code PRIO-233
EtherNet/IP Scn Not in Run Mode
View solution Code PRIO-268
IO LinkII(M) RX Buf overflow
View solution Code PRIO-280
FL-net System Error(%d)
View solution Code PRIO-281
FL-net PCB not installed
View solution Code PRIO-282
FL-net PCB Abnormal(%d)
View solution Code PRIO-283
FL-net IP Address Incorrect
View solution Code PRIO-284
FL-net Token Interval Error
View solution Code PRIO-285
FL-net Init Error
View solution Code PRIO-286
FL-net Wait Frame Status
View solution Code PRIO-287
FL-net My Node Dupulicate No.
View solution Code PRIO-288
FL-net My Node Leave network
View solution Code PRIO-289
FL-net My Node Enter network
View solution Code PRIO-290
FL-net My Node Dupulicate Adr
View solution Code PRIO-291
FL-net Node %d Leave network
View solution Code PRIO-292
FL-net Node %d Enter network
View solution Code PRIO-293
FL-net Dupulicate Area Adr %d
View solution Code PRIO-294
FL-net Multiple PCBs detected
View solution Code PRIO-320
CC-LK System error(ID=%x)(%d)
View solution Code PRIO-321
CC-LK Board not installed
View solution Code PRIO-322
CC-LK St.No out of range(%d)
View solution Code PRIO-323
CC-LK CRC error(%d)
View solution Code PRIO-324
CC-LK Data link error(%d)
View solution Code PRIO-325
CC-LK Seq. CPU stopped(%d)
View solution Code PRIO-326
CC-LK Seq. CPU abnormal(%d)
View solution Code PRIO-327
CC-LK Reg index error(%d)
View solution Code PRIO-328
CC-LK AO/R too many(%d)
View solution Code PRIO-329
CC-LK AI/R too many(%d)
View solution Code PRIO-330
CC-LK PNTtoUOP not enough(%d)
View solution