代码 912: APC No P Code Or Q Code For M46

问题描述与安全警告

Haas VF-Series CNC 触发了严重的 APC No P Code Or Q Code For M46 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

M46 must have a P code and a Q code. The P code must be the name of a program stored in memory. The Q code is the number of the pallet to run the program on. 913 APC No P Code or Q Code For M49 M49 must have a Q code. The Q code is the status to give the pallet. 914 APC Invalid P Code The P code must be the name of a program stored in memory. The program name must not have a decimal point. Remove any decimal points from the program name. 915 APC Illegal Nesting G188 or M48 G188 is only legal in main program. M48 is only legal in a program listed in the Pallet Schedule Table or a first level subprogram. 916 APC Negative PAL Priority Index Software Error; Call your dealer. 917 APC Number Of Pallets Is Zero Parameter 606 must have a value if parameter 605 is not zero. Set parameter 606 to the number of pallets in your FMS system. 918 APC Load Switch Missed PAL 1 Pallet #1 did not complete its move from the APC to the receiver in the allowable time. Pallet change sequence was halted because receiver switch was not activated. Pallet is either unclamped or not on the receiver. Ensure the pallet is correctly located on receiver (against hard stop) then run M18 to clamp the pallet. After correcting the condition, run an M50 to continue machining. 919 APC Load Switch Missed Pal 2 Pallet #2 did not complete its move from the APC to the receiver in the allowable time. Pallet change sequence was halted because receiver switch was not activated. Pallet is either unclamped or not on the receiver. Ensure the pallet is correctly located on receiver (against hard stop) then run M18 to clamp the pallet. After correcting the condition, run an M50 to continue machining. 920 APC Load Switch Missed PAL 3 Pallet #3 did not complete its move from the APC to the receiver in the allowable time. Pallet change sequence was halted because receiver switch was not activated. Pallet is either unclamped or not on the receiver. Ensure the pallet is correctly located on receiver (against hard stop) then run M18 to clamp the pallet. After correcting the condition, run an M50 to continue machining. 921 APC Load Switch Missed PAL 4 Pallet #4 did not complete its move from the APC to the receiver in the allowable time. Pallet change sequence was halted because receiver switch was not activated. Pallet is either unclamped or not on the receiver. Ensure the pallet is correctly located on receiver (against hard stop) then run M18 to clamp the pallet. After correcting the condition, run an M50 to continue machining. 922 APC Table Not Declared Software calling invalid tables. Software Error; Call your dealer. 923 A Indexer Is Not At The Proper Incremental Position The indexer has moved to a position that cannot be seated. 924 B Indexer Is Not At The Proper Incremental Position The indexer has moved to a position that cannot be seated. 925 A Indexer Is Not Fully In The Up Position The indexer is still seated. It is not completely in the up position and cannot be rotated. Reset then rezero the indexer. 926 B Indexer Is Not Fully In The Up Position The indexer is still seated. It is not completely in the up position and cannot be rotated. Reset then rezero the indexer. 927 Illegal G1 Code For Rotary Indexer The rotary indexer only does rapid G0 motion. Feed G1 motion is not allowed. 937 ATC Parameter Error There is an error with tool changer parameter values. Parameters 223 and 254 must both have non-zero values for the side-mount tool changer with a tool changer air door. 940 Side Mount Carousel Error This alarm supports the side mount tool changers. It is generated if the carousel motor is still on when the tool pocket is unlocked and lowered prior to a tool change. 941 Pocket Tool Table Error This alarm is generated by a side mount tool changer if the tool specified by the G-code program is not found in the POCKETTOOL table, or the searching pocket is out of range. 942 Carousel Position Timeout This alarm supports the side mount tool changers. It is generated if the tool carousel has not moved after the allowed time or has not stopped after the allowed time specified by parameter 60 TURRET START DELAY and parameter 61 TURRET STOP DELAY, respectively. Alarms 1000-1999 are user defined by macro programs.

Source: Haas VF-Series Service Manual (96-8100 rev G, 2003)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Haas VF-Series CNC 警报

由 Haas 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 VF-Series CNC 出现类似 912 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 461 Haas VF-Series CNC 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code 912.

Manual conversion service

Need a searchable reference for more Haas VF-Series CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相关的 Haas VF-Series CNC 代码