代码 126-0117: PLC output for switch-off is improperly configured
问题描述与安全警告
Heidenhain TNC Series CNC 触发了严重的 PLC output for switch-off is improperly configured 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
[Cause of error] The PLC output for switching off the machine after the control has been shutdown was incorrectly configured. The settings in the configuration datum CfgShutdown are not applicable for an integrated PL (e.g. with UEC, UMC) nor for a PL connected over HSCI (e.g. PLB 62xx). Settings for output on internal PL: - powerOffDevice: Unassigned - powerOffSlot: Unassigned - powerOffPort: Number of the output on internal PL (value range: 0 to 30) Settings for output on a PL connected over HSCI: - powerOffDevice: Bus address of the PL - powerOffSlot: Slot number of the module (0 for system module and UEC11x) - powerOffPort: Number of the output to be switched [Error correction] - Check the configuration data (machine parameter number 101600) - Inform your service agency
Source: HEIDENHAIN NC Error Messages — TNC7/640/620/320/128, CNC PILOT 640, MANUALplus 620 (10/2023)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Heidenhain TNC Series CNC 警报
由 Heidenhain 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 TNC Series CNC 出现类似 126-0117 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 4497 Heidenhain TNC Series CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 126-0117.
Need a searchable reference for more Heidenhain TNC Series CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026