代碼 231-8080: Uz UV 1xx exceeds max.
問題描述與安全警告
Heidenhain TNC Series CNC 觸發了嚴重的 Uz UV 1xx exceeds max. 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
[Cause of error] - DC-link voltage of the power supply unit too high - Defective braking resistor - Defective power supply unit (infeed/regenerative feedback module) - Interruption in the primary supply (fuses, wires, etc.) - Energy recovery not possible [Error correction] - Inform your service agency - Check the configuration datum (braking of the spindle) - Check the braking resistor - Replace the power supply unit - Check the fuses and wiring of the primary supply
Source: HEIDENHAIN NC Error Messages — TNC7/640/620/320/128, CNC PILOT 640, MANUALplus 620 (10/2023)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Heidenhain TNC Series CNC 警報
由 Heidenhain 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 TNC Series CNC 出現類似 231-8080 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。