代碼 231-A082: CC%2 NE2 level does not change after 0 during dyn.
問題描述與安全警告
Heidenhain TNC Series CNC 觸發了嚴重的 CC%2 NE2 level does not change after 0 during dyn. 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
test [Cause of error] - During the dynamic test of the 2nd emergency stop loop (every 1.5 minutes at the latest), a temporary change to 0 V level is expected at the input (NE2). If a 0 V or 24 V level remains continuously on inside the test window of 100 ms, it causes the error. - The time window for the dynamic test is too small (computing time problems, software errors) [Error correction] - Check the software version - Inform your service agency - Check the wiring - Check the emergency stop button - Exchange the hardware
Source: HEIDENHAIN NC Error Messages — TNC7/640/620/320/128, CNC PILOT 640, MANUALplus 620 (10/2023)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.