代码 231-E190: RDY.x status of axes stays active (safety relay) %1
问题描述与安全警告
Heidenhain TNC Series CNC 触发了严重的 RDY.x status of axes stays active (safety relay) %1 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。
官方故障排除步骤
[Cause of error] - Measured status of the '-STO.A.G' signals remain inactive during the test (high level) - The '-STO.A.G' signal does not change to the 'active' status (low level), even though the MC sets the corresponding signal status - The power stage (inverter) of at least 1 feed axis or auxiliary axis is not locked through the '-STO.A.G' signal. [Error correction] - Check the wiring - Hardware defective - Inform your service agency
Source: HEIDENHAIN NC Error Messages — TNC7/640/620/320/128, CNC PILOT 640, MANUALplus 620 (10/2023)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
关于 Heidenhain TNC Series CNC 警报
由 Heidenhain 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 TNC Series CNC 出现类似 231-E190 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。
完整报警清单: 4497 Heidenhain TNC Series CNC 代码s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 231-E190.
Need a searchable reference for more Heidenhain TNC Series CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.