代碼 231-E1E0: CC%2 RDY.x status remains active (safety relay)%1
問題描述與安全警告
Heidenhain TNC Series CNC 觸發了嚴重的 CC%2 RDY.x status remains active (safety relay)%1 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
[Cause of error] - An error occurred during the watchdog test WD.A.STO of the PL 6xxxFS. A power stage (inverter) is not switched off through the -STOS.A.G or -STO.A.G signal. - Faulty or missing wiring of -STO.A.G, -STOS.A.G or X71, X72 of the power module (UV, UE) - Error in parameters of the control of X71, X72 through STO.A.G, -STOS.A.G in SMP - Hardware defective [Error correction] - Check the wiring - Check SMP - Exchange the hardware - Generate the service files and notify the Service Department
Source: HEIDENHAIN NC Error Messages — TNC7/640/620/320/128, CNC PILOT 640, MANUALplus 620 (10/2023)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Heidenhain TNC Series CNC 警報
由 Heidenhain 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 TNC Series CNC 出現類似 231-E1E0 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 4497 Heidenhain TNC Series CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 231-E1E0.
Need a searchable reference for more Heidenhain TNC Series CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026