代码 M01-0021: Tool ofs invld after R-pnt

问题描述与安全警告

Mitsubishi M800/M80 CNC 触发了严重的 Tool ofs invld after R-pnt 警报。需要由合格的操作员或维修技师立即处理,以防止在制造周期中对设备造成二次损坏或导致零件报废。在接触电气控制箱之前,请务必确保遵循标准安全和停机挂牌 (LOTO) 程序。

官方故障排除步骤

Details Reference position return had been performed during the tool retract and return, which invalidated the tool com- pensation amount after the reference position return. Remedy  The error is cleared if the operation mode is changed to other than reference position return before the axis performs reference position return.  The error is cleared when the tool return is completed.  The error is cleared if reset 1 is inpu t or the emergency stop button is pushed. R-pnt ret invl d at abs pos alm 0024 Details A reference position return signal was enabled during an absolute position detection alarm. Remedy  Reset the absolute position detection alarm, and then perform the reference position return. R-pnt ret invld at zero pt ini 0025 Details A reference position return signal was input during zero point initialization of the absolute position detection system. Remedy  Complete the zero point initialization, and then perform reference position return. High-accuracy skip disabled 0028 Details The drive unit's hardware or software does not conform to the high-accuracy skip. Remedy  The software or hardware does not conform to the function. Contact service center. Hi-ac skip coord retrieval err 0029 Details Failed to retrieve the skip coordi nate value from the drive unit. Remedy  Check the wiring.  Check the parameters. Now skip on 0030 Details The "skip input" signal remains enabled when the operat ion has shifted from skip retract to measurement. Remedy  Increase the skip retract amount. No skip 0031 Details Even though the 1st skip was to the correct position, the 2nd skip could not be found. Remedy  Check whether the measurement target has moved. Rtn dir err in manual measure 0033 Details Return direction in manual measurement is the opposite of the parameter setting. Remedy  Check the setting of the parameter "#2169 Rtn dir e rr in manual measure" (Return direction in manual measurement).  Move the axis manually in the direction to a safe position, then reset. No specifications 0036 Details The specification is not supported. Remedy  Check the specifications.

Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

关于 Mitsubishi M800/M80 CNC 警报

由 Mitsubishi 制造的工业控制器具有广泛的诊断系统,用于保护内部电路和机械连杆。当 M800/M80 CNC 出现类似 M01-0021 的错误代码时,通常表示指令值与实际传感器反馈之间存在不匹配。

完整报警清单: 722 Mitsubishi M800/M80 CNC 代码s.

Have a better solution?

Help the industrial community by sharing your repair experience for code M01-0021.

Manual conversion service

Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相关的 Mitsubishi M800/M80 CNC 代码