Código M01-0056: Tap pitch/thr ead number error
Descripción del problema y advertencia de seguridad
El Mitsubishi M800/M80 CNC ha desencadenado una alarma crítica Tap pitch/thr ead number error. Se requiere la atención inmediata de un operador calificado o técnico de mantenimiento para evitar daños secundarios al equipo o piezas estropeadas durante el ciclo de fabricación. Asegúrese siempre de seguir los procedimientos de seguridad estándar y LOTO antes de acceder a los armarios eléctricos.
Pasos oficiales de solución de problemas
Details The command for the pitch or the number of threads is not correct in the synchron ous tapping command of the multiple-spindle control II. The pitch is too small for the spindle rotation speed. Thread number is too large for the spindle rotation speed. Remedy Correct the pitch, number of threads or rotation speed of the tapping spindle. Wait for tap retract 0057 Details The axis travel command is interlocked as the tap retract is being enabled. Remedy If tapping is necessary, perform tapping retract in ad vance. However, tapping retract is not allowed during cycle start operation. Carry out tapping retract after resetting. If tapping is not necessary, cancel the tap retract en abled condition by the tap retract enabled cancel sig- nal. Handle ratio too large 0060 Details The handle ratio is too large for the handle feed clamp speed. (The handle feed clamp speed changes according to the rapid traverse rate, external feedrate, maximum speed outside the soft limit range and etc. (or external deceleration speed when external deceleration is valid)) Too large handle ratio means the ratio with which the mach ine is unable to move the distance of [iunit * handle ratio] within 0.1ms at the clamp speed. Example) When iunit=B (0.001mm) a nd clamp speed cs (mm/min) The operation error (M01 0060) will occur if ratio M>cs/60(s)*0.1(ms )/0.001(mm)=cs*10/6. Remedy Change the settings of the handle fe ed clamp speed or the handle ratio. R-pos offset value illegal 0065 Details At the start of reference position initial setting, the parameter "#2034 rfpofs" (Dis tance-coded reference position detection offset) is not set to "0". Remedy Set the parameter "#2034 rfpofs" to "0", then turn the power ON again to perform the reference position initial setting. R-pos scan distance exceeded 0066 Details Reference position could not be estab lished within the maximum scan distance. Remedy Check the scale to see if it has dirt or damage. Check if the servo drive unit supports this function. Illegal op in wk instl err cmp 0070 Details One of the following operations was attempted du ring workpiece installation error compensation. Manual interruption Automatic operation handle interruption MDI interruption PLC interruption Remedy Return the operation mode to the original mode to remove the cause. During workpiece installation error compensation, manual interruption, automatic operation handle interruption, MDI interruption, PLC inter- ruption, etc. is not allowed.
Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Acerca de las alarmas de Mitsubishi M800/M80 CNC
Los controladores industriales construidos por Mitsubishi están diseñados con amplios sistemas de diagnóstico para proteger los circuitos internos y los enlaces mecánicos. Cuando un M800/M80 CNC arroja un código de error como M01-0056, generalmente indica un desajuste entre los valores ordenados y la retroalimentación real del sensor.
Lista completa de alarmas: 722 Mitsubishi M800/M80 CNC códigos.
Have a better solution?
Help the industrial community by sharing your repair experience for code M01-0056.
Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026