代碼 M01-1014: GB spindle synchro signal OFF
問題描述與安全警告
Mitsubishi M800/M80 CNC 觸發了嚴重的 GB spindle synchro signal OFF 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Details A forward run, reverse run, orientation, synchronous tapping, spindle synchroni zation, tool spindle syn- chronization I, tool spindle synchronization II or C- axis servo ON command was issued to the reference spindle while the guide bushing spindle synchronization signal was OFF. The guide bushing spindle synchronization signal was turned OFF during a forward run, reverse run, ori- entation, synchronous tapping, spindle synchronization, t ool spindle synchronization I, tool spindle synchro- nization II or C-axis servo ON command. Orientation was commanded during the "guide bushing spindle synchronization" signal ON with spindle zero point detection with proximit y switch and turret indexing enabled. C axis servo ON was commanded during the "guide bushing spindle synchronization" signal ON with spin- dle C axis parameter change enabled. Remedy Check the ladder program. Check the parameters. GB SP sync:Spindle type error 1015 Details An analog spindle is used for the master spindle or the guide bushing spindle. Spindle-mode servo is used for the master spindle or the guide bushing spindle. Turret gear change control valid spindle is used for the master spindle or the guide bushing spindle. Remedy Check the parameters. Change the reference spindle or the guide bushing spindle to spindle drive unit. Change the reference spindle or the guide bushin g spindle to turret gear change control invalid. GB SP sync:Phase mem sgnl ilgl 1021 Details The guide bushing spindle synchronization phase memory signal was turned ON while the master spindle or guide bushing spindle was rotating. The guide bushing spindle synchronization phase memory signal was turned ON while the guide bushing spindle synchronization signal was OFF. Remedy Check the ladder program. GB SP sync:Phase set sgnl ilgl 1022 Details The guide bushing spindle synchronization phase alignment signal was turned ON while the master spin- dle or guide bushing spindle was stopped. Remedy Check the ladder program. GB SP sync:Z phase not pass 1023 Details When the guide bushing spindle synchronization phase memory signal was ON, the master spindle or guide bushing spindle’s Z-phase was not passed. Remedy Check the ladder program. Cmnd impsbl in spindle rtry ax 1024 Details Toward the synchronous tapping spindle, the switch to servo-mode is commanded to the spindle-mode rotary axis. The spindle-mode rotary axis in servo-mode is commanded as the synchronous tapping spindle. Remedy Switch to the spindle-mode rotary axis. Other cmnd disabled in orient. 1025 Details Spindle superimposition control command has been gi ven to an orientation mode spindle with the said spindle treated as either the reference or superimposed spindle. Orientation command has been given to the reference or superimposed spindle that is under spindle su- perimposition control. Remedy Cancel the orientation mode. Use G113 or the "Spindle sync cancel" signal to cancel spindle superimposition.
Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Mitsubishi M800/M80 CNC 警報
由 Mitsubishi 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 M800/M80 CNC 出現類似 M01-1014 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 722 Mitsubishi M800/M80 CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code M01-1014.
Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026