コード M01-1255: Multiple secondary ax selected

問題の説明と安全警告

Mitsubishi M800/M80 CNC は重大な Multiple secondary ax selected アラームをトリガーしました。製造サイクル中に機器への二次的損傷や部品の破損を防ぐために、資格のあるオペレーターまたはメンテナンス技術者による直ちの対応が必要です。電気キャビネットにアクセスする前に、必ず標準の安全およびLOTO手順が遵守されていることを確認してください。

公式トラブルシューティング手順

Details For the multiple axis synchronization control, you sele cted two or more slave axes without selecting any master axis. Remedy  Correct the setting of R2589 (Synchronou s control operation method selection). Cmnd invalid during VCC mode 1300 Details The issued command is disabled dur ing the vibration cutting mode. Remedy  Correct the program. VCC mode command invalid 1301 Details Vibration cutting mode start command has been issued al though the command is dis abled during the currently active mode. Remedy  Correct the program. VCC invalid 1302 Error cause number Details [When error cause No. is 0001] Cutting is being performed without vibration cutting control. [When error cause No. is 0002] Vibration cutting is being performed with OMR-FF being disabled. Remedy [When error cause No. is 0001]  Make sure that the "VCC: Temporary cancel of axis vibration" signal (R22532) is OFF.  Make sure that the spindle speed command is not "0" when the cutting command is issued.  Make sure that neither synchroni zed axis nor superimposed axis is included in the part system. [When error cause No. is 0002]  Make sure that the servo parameter "#2313 SV113" bit0 is "1" and bit1 is "0" for the VCC objective axes. Feedrate limited during VCC 1303 Details The feedrate command issued during the vibration cu tting mode is exceeding "#12571 VibClamp_VCC". Remedy  Correct the program. VCC condition not found 1304 Details No applicable condition is found during the selection of the vibration cutting condition. Remedy  Correct the program.  Check the setting of the frequency upper limit "#12131 FrqClmpSys_VCC".  Check the settings of the maximum spindle rotation speed "#3005 smax1" to "#3008 smax4" and the min- imum rotation speed "#3023 smini". Cannot change SP speed in VCC 1307 Details You changed the spindle rotation speed during vibration cutting control. Remedy  Wait for completion of vibration cutting cont rol, or input Reset to cancel the VCC mode. Cannot re-run SP during VCC 1308 Details You stopped the spindle during vibration cuttin g control, and then attempted to re-run it. Remedy  If you have stopped the spindle during vibration cutting control, input Reset to ca ncel the VCC mode before re-running the spindle.

Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

Mitsubishi M800/M80 CNC のアラームについて

Mitsubishi によって構築された産業用コントローラーは、内部回路と機械的リンケージを保護するための広範な診断システムで設計されています。M800/M80 CNC が M01-1255 のようなエラーコードをスローする場合、通常、指令値と実際のセンサーフィードバック間の不一致を示します。

完全アラーム一覧: 722 Mitsubishi M800/M80 CNC コードs.

Have a better solution?

Help the industrial community by sharing your repair experience for code M01-1255.

Manual conversion service

Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

関連する Mitsubishi M800/M80 CNC コード