コード T01-0165: Cycle st. prohibit(safe speed)
問題の説明と安全警告
Mitsubishi M800/M80 CNC は重大な Cycle st. prohibit(safe speed) アラームをトリガーしました。製造サイクル中に機器への二次的損傷や部品の破損を防ぐために、資格のあるオペレーターまたはメンテナンス技術者による直ちの対応が必要です。電気キャビネットにアクセスする前に、必ず標準の安全およびLOTO手順が遵守されていることを確認してください。
公式トラブルシューティング手順
Details An automatic operation was started in one of the following machining modes during the safe speed clamp: thread cutting, synchro nous tapping, cross machining, superimposition control, tool center point control or SSS control. Remedy Turn ON the safely-limited speed monitoring request signal and press the cycle start button. Close the door and press the cycle start button. Cycle start prohibit (AL Z83) 0172 Details Cycle start is disabled while the system alarm Z83 (NC started during SP rotation) is occurring. Remedy Turn OFF the power and make sure that the spindle is at a standstill. And then turn the power ON again. In interference check alarm 0173 Details Cycle start cannot be operated because interference check alarm is in progress. Remedy Release the interference check alarm before operating the cycle start. Cycle st forbid (measuring err) 0176 Details Cycle start cannot be exec uted for other part systems duri ng measurement of rotation center error or workpiece installation error. Remedy Execute cycle start for one part system that is ready for measurement. Cancel measurement when error measurement is not executed. Cycle start prohibit (OP error) 0177 Details Cycle start was executed during operation e rror where cycle start cannot be executed. Remedy After canceling o peration error, ex ecute cycle start. Cycle start prohibit(SBT warn) 0185 Details Cycle start is disabled be cause the axis in SBT warning exists in the system. Remedy After cancelling the SBT warn ing, execute the cycle start. Cycle start prohibit 0190 Details Automatic start is not possible because the setting of setup parameters is enabled. Remedy Refer to the manual issued by the machine tool builder. Cycle start prohibit 0191 Details Automatic start was attempted while a file was being deleted/written. Remedy Wait for the file to be deleted/writt en and then execute the automatic start. Cycle st. prohibit (Term exp'd) 0193 Details Automatic start is not possible because the valid term has been expired. Remedy Obtain a decryption code from the machine tool builder and input it in the NC, then turn the power ON again.
Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Mitsubishi M800/M80 CNC のアラームについて
Mitsubishi によって構築された産業用コントローラーは、内部回路と機械的リンケージを保護するための広範な診断システムで設計されています。M800/M80 CNC が T01-0165 のようなエラーコードをスローする場合、通常、指令値と実際のセンサーフィードバック間の不一致を示します。
完全アラーム一覧: 722 Mitsubishi M800/M80 CNC コードs.
Have a better solution?
Help the industrial community by sharing your repair experience for code T01-0165.
Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026