Code V05-0006: SOS travel distance error

Issue Description & Safety Warning

The Mitsubishi M800/M80 CNC has triggered a critical SOS travel distance error alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

Details The command/FB travel distance, which had exceeded th e SOS travel distance tolerance (+/-) (set by param- eter) during SOS, has failed to reduce to the SOS travel distance tolerance (+/-) or smaller within the SOS_P detection delay time (set by parameter). The screen displays the name of axis of this error. *If the conditions of two or more SOS -related alarms are met at a time, the notification priority order is as fol- lows: SOS position deviation error > SOS travel distance error > SOS speed error. Remedy  Refer to the corrective actions of "SOS speed error" for how to cancel this error.  If the SOS travel distance tolerance (+/-) (set by parameter) is smaller than the assumption, change the setting and turn OFF and ON the power.  If the SOS_P detection delay time (set by parameter) is shorter than the assumption, change the param- eter setting.

Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Mitsubishi M800/M80 CNC Alarms

Mitsubishi controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code V05-0006 on the M800/M80 CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Mitsubishi's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 722 Mitsubishi M800/M80 CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code V05-0006.

Manual conversion service

Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Mitsubishi M800/M80 CNC Codes