代碼 V50-002: Smart Safety Observation Warning

問題描述與安全警告

Mitsubishi M800/M80 CNC 觸發了嚴重的 Smart Safety Observation Warning 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。

官方故障排除步驟

 After enabling SLP/SCA (Parameter SLP_Enable/SCA_Enab le is 1), the Safety absolute position has nev- er been established.  In SLP/SCA encoder diagnosis during power OFF, [saved position at power shut OFF] and [restored po- sition at power ON] are inconsistent. While this alarm is ON, SLP/SCA will not operate . Displays the name of axis of this error. Remedy  This alarm can be cancelled by turning ON the Safety absolute position check signal. Before turning ON the Safety absolute position check signal, however, move the axis by manual operation to the position where the coordinate value is clear (the position that is marked or the reference position etc.) (When in the relative position detection system, it requires to operat e reference position return to establish the reference position.) then compare the actual position and the di splayed position to confirm the both position is corre- sponding. SBT start disabled 0001 Factor No.

Source: Mitsubishi M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

關於 Mitsubishi M800/M80 CNC 警報

由 Mitsubishi 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 M800/M80 CNC 出現類似 V50-002 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。

完整警報清單: 722 Mitsubishi M800/M80 CNC 代碼s.

Have a better solution?

Help the industrial community by sharing your repair experience for code V50-002.

Manual conversion service

Need a searchable reference for more Mitsubishi M800/M80 CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

相關的 Mitsubishi M800/M80 CNC 代碼