代碼 F00041: Motor Data Identification Failure
問題描述與安全警告
Siemens SINAMICS G120 CU240S Drive 觸發了嚴重的 Motor Data Identification Failure 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Reaction: OFF 2 Acknowledge: Quit fault eg. via DI2 Cause: Motor data identification failed. - r0949 = 0: Load missing - r0949 = 1: Current limit level reached during identification. - r0949 = 2: Identified stator resistance less than 0.1% or greater than 100%. - r0949 = 3: Identified rotor resistance less than 0.1% or greater than 100%. - r0949 = 4: Identified stator reactance less than 50% and greater than 500% - r0949 = 5: Identified main reactance less than 50% and greater than 500% - r0949 = 6: Identified rotor time constant less than 10ms or greater than 5s - r0949 = 7: Identified total leakage reactance less than 5% and greater than 50% - r0949 = 20: Identified IGBT on-voltage less than 0.5 V or greater than 10 V - r0949 = 30: Current controller at voltage limit - r0949 = 40: Inconsistence of identified dataset, at least one identification failed - r0949 = 41: Writing of calculated magnetizing current P0320 failed - r0949 = 42: Writing of identified stator resistance failed - r0949 = 43: Writing of identified rotor resistance P0354 failed - r0949 = 44: Writing of identified rotor time constant P0622 failed - r0949 = 45: Writing of identified mutual reactance P0360 failed - r0949 = 46: Writing of identified stator leakage reactance P0356 failed - r0949 = 47: Writing of identified rotor leakage reactance P0358 failed - r0949 = 48: Writing of identified on voltage P1825 failed. - r0949 = 49: Writing of the identified dead time compensation P1828 failed Percentage values based on the impedance Zb = Vmot,nom / sqrt(3) / Imot,nom Remedy: Check the following: - r0949 = 0: is the motor connected to the inverter. - r0949 = 1-49: are the motor data in p0304 - p0311 correct. - Check what type of motor wiring is required (star, delta).
Source: SINAMICS G120 Control Units CU240S Faults and Alarms (Edition 05/2007)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Siemens SINAMICS G120 CU240S Drive 警報
由 Siemens 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 SINAMICS G120 CU240S Drive 出現類似 F00041 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code F00041.
Need a searchable reference for more Siemens SINAMICS G120 CU240S Drive manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026