代碼 F00090: Encoder feedback loss
問題描述與安全警告
Siemens SINAMICS G120 CU240S Drive 觸發了嚴重的 Encoder feedback loss 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Reaction: OFF 2 Acknowledge: Quit fault eg. via DI2 Cause: Signal from Encoder lost (check fault value r0949): - r0949 = 0: Encoder signal lost. - r0949 = 1: Encoder loss detected due to sudden speed change (i.e. speed change detected on encoder in a single scan > value in P0492). - r0949 = 2: Encoder signal lost whilst running at low speed. - r0949 = 5: Encoder not configured in p0400, but required for sensored control (p1300 = 21 or 23). - r0949 = 6: Encoder not found, but configured in p0400. - r0949 = 7: Encoder loss detected due to motor stalled. Remedy: Stop the inverter. - r0949 = 2, Increase value of p0494 or reduce value of p1120 and p1121. - r0949 = 5, select encoder type via p0400. - r0949 = 5, select SLVC mode (p1300 = 20 or 22). - r0949 = 7, select SLVC mode (p1300 = 20 or 22). - Check connections between encoder and inverter. - Check that encoder not faulty (select p1300 = 0, run at fixed speed, check encoder feedback signal in r0061) - Increase encoder loss threshold in p0492.
Source: SINAMICS G120 Control Units CU240S Faults and Alarms (Edition 05/2007)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Siemens SINAMICS G120 CU240S Drive 警報
由 Siemens 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 SINAMICS G120 CU240S Drive 出現類似 F00090 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
Have a better solution?
Help the industrial community by sharing your repair experience for code F00090.
Need a searchable reference for more Siemens SINAMICS G120 CU240S Drive manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.