Code F01612: Diff. in hardw. detection

Issue Description & Safety Warning

The Siemens SINAMICS G120 CU240S Drive has triggered a critical Diff. in hardw. detection alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

Reaction: OFF 2 (OFF 3) Acknowledge: Quit fault eg. via DI2 Cause: The hardware (safety or non-safety hardware) could no be identified. - r0949 = 100: Identification error during startup on P1. - r0949 = 101: Runtime detection error on P1. - r0949 = 102: Hardware or software configuration error on P1. - r0949 = 200: Startup error on P2. - r0949 = 201: Runtime detection error on P2. - r0949 = 202: Hardware or software configuration error on P2. Remedy: - Inverter hardware is faulty or problem in processor communication. Perform a power cycle.

Source: SINAMICS G120 Control Units CU240S Faults and Alarms (Edition 05/2007)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Siemens SINAMICS G120 CU240S Drive Alarms

Siemens controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code F01612 on the SINAMICS G120 CU240S Drive identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Siemens's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 108 Siemens SINAMICS G120 CU240S Drive codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code F01612.

Manual conversion service

Need a searchable reference for more Siemens SINAMICS G120 CU240S Drive manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Siemens SINAMICS G120 CU240S Drive Codes