代碼 F01616: Processor selftest faulty
問題描述與安全警告
Siemens SINAMICS G120 CU240S Drive 觸發了嚴重的 Processor selftest faulty 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Reaction: OFF 2 (OFF 3) Acknowledge: Quit fault eg. via DI2 Cause: The processor selftest has uncovered an error: - r0949 = 100: General error on P1. - r0949 = 101: Error in RAM test on P1. - r0949 = 102: Error in ROM test on P1. - r0949 = 103: Error in processor function test on P1. - r0949 = 200: Error in processor self-test on P2. The selftest is started together with the forced dynamisation and must be enabled by setting p9601.1 and p9801.1. Remedy: - Run self-test again (set bit 1 in p9601 and p9801 and enter the STO mode, then leave the STO mode again).
Source: SINAMICS G120 Control Units CU240S Faults and Alarms (Edition 05/2007)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Siemens SINAMICS G120 CU240S Drive 警報
由 Siemens 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 SINAMICS G120 CU240S Drive 出現類似 F01616 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。