代碼 10758: [Channel %1: ] Block %2 curvature radius with variable compensation value too small
問題描述與安全警告
Siemens SINUMERIK 840D CNC 觸發了嚴重的 [Channel %1: ] Block %2 curvature radius with variable compensation value too small 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Parameters: %1 = Channel number %2 = Block number, label Definitions: The current cutter radius compensation (the cutter us ed) is too large for the programmed path radius. In a block with variable tool radius compensatio n, a compensation must be possible either anywhere or nowhere on the contour with the smallest and the largest compensation value from the programmed range. There must be no point on the contour in whic h the curvature radius is within the variable compensation range. If the compensation value varies its sign within a bl ock, both sides of the contour are checked, otherwise only the compensation side. Reaction: Correction block is reorganized. Local alarm reaction. Interface signals are set. Alarm display. NC Stop on alarm at block end. Remedy: Use smaller cutters or allow for a part of the cu tter radius at the time of contour programming. Program Continuation: Clear alarm with NC ST ART or RESET key and continue the program.
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Siemens SINUMERIK 840D CNC 警報
由 Siemens 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 SINUMERIK 840D CNC 出現類似 10758 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 4014 Siemens SINUMERIK 840D CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 10758.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.