Code 12570: [Channel %1: ] Block %2 too many motion synchronous actions in %3
Issue Description & Safety Warning
The Siemens SINUMERIK 840D CNC has triggered a critical [Channel %1: ] Block %2 too many motion synchronous actions in %3 alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Parameters: %1 = Channel number %2 = Block number, label %3 = Source symbol Definitions: No more than 16 actions are allowed in a block with motion synchronous action. Reaction: Correction block is reorganized. Interface signals are set. Alarm display. Remedy: Reduce the number of programmed actions. Program Continuation: Clear alarm with NC ST ART or RESET key and continue the program.
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Siemens SINUMERIK 840D CNC Alarms
Siemens controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 12570 on the SINUMERIK 840D CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Siemens's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 4014 Siemens SINUMERIK 840D CNC codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code 12570.