Code 14790: [Channel %1: ] Block %2 axis %3 programmed by PLC
Issue Description & Safety Warning
The Siemens SINUMERIK 840D CNC has triggered a critical [Channel %1: ] Block %2 axis %3 programmed by PLC alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Parameters: %1 = Channel number %2 = Block number, label %3 = Axis Definitions: In the NC block, an axis has been programmed that is already being traversed by the PLC. Reaction: Correction block is reorganized. Interface signals are set. Alarm display. Diagnostics Manual (DAsl), 03/2009 Remedy: - Modify part program, do not use this axis. - Stop traversing motion of the axis by the PLC, modify part program (insert WAITP). Program Continuation: Clear alarm with NC ST ART or RESET key and continue the program.
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Siemens SINUMERIK 840D CNC Alarms
Siemens controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 14790 on the SINUMERIK 840D CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Siemens's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 4014 Siemens SINUMERIK 840D CNC codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code 14790.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026