Code 16934: [Channel %1: ] Interrupt treatment: action %2<ALNX> not possible due to stop

Issue Description & Safety Warning

The Siemens SINUMERIK 840D CNC has triggered a critical [Channel %1: ] Interrupt treatment: action %2<ALNX> not possible due to stop alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.

Official Troubleshooting Steps

Parameters: %1 = Channel ID %2 = Action number/action name Diagnostics Manual (DAsl), 03/2009 Definitions: Reorg events are, e.g. abort subprogram, delete di stance to go and interrupts, axis exchange, termination of follow-up mode. Two Reorg events overlap in this situation. The 2nd Reorg event coincides with the 1st block generated by the previous ev ent. (e.g. an axis exchange is induced twice in rapid succession). Axis exchange leads to Reorg in the c hannels in which an axis is removed without preparation. This block must be stopped in the above sequence in order to prevent the interpolator buffer from overflowing. This can be achi eved by pressing the Stop or StopAll key, configuring an alarm with INTERPRETERSTOP or by decode single block. Reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Remedy: The program must be aborted with Reset. Program Continuation: Clear alarm with the RESET key. Restart part program

Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

About Siemens SINUMERIK 840D CNC Alarms

Siemens controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 16934 on the SINUMERIK 840D CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Siemens's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.

Complete Alarm List: 4014 Siemens SINUMERIK 840D CNC codes.

Have a better solution?

Help the industrial community by sharing your repair experience for code 16934.

Manual conversion service

Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

Related Siemens SINUMERIK 840D CNC Codes