コード 17502: [Channel %1: ] Block %2 indexing axis %3 with Hirth tooth system stop is delayed
問題の説明と安全警告
Siemens SINUMERIK 840D CNC は重大な [Channel %1: ] Block %2 indexing axis %3 with Hirth tooth system stop is delayed アラームをトリガーしました。製造サイクル中に機器への二次的損傷や部品の破損を防ぐために、資格のあるオペレーターまたはメンテナンス技術者による直ちの対応が必要です。電気キャビネットにアクセスする前に、必ず標準の安全およびLOTO手順が遵守されていることを確認してください。
公式トラブルシューティング手順
Parameters: %1 = Channel number %2 = Block number, label %3 = Axis name Definitions: For the indexing axis, the 'Hirth tooth system' fu nction is activated and the override has been set to 0 or another stop condition (e.g. VDI interface signal) is active. Since it is possi ble to stop only on indexing axes, the next possible indexing position is appr oached. The alarm is displayed until this position is reached or the stop condition is deactivated. Reaction: Alarm display. Remedy: Wait until the next possible index ing position is reached or set override > 0 or deactivate another stop condition. Program Continuation: Alarm display showing cause of alarm disapp ears. No further operator action necessary.
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
Siemens SINUMERIK 840D CNC のアラームについて
Siemens によって構築された産業用コントローラーは、内部回路と機械的リンケージを保護するための広範な診断システムで設計されています。SINUMERIK 840D CNC が 17502 のようなエラーコードをスローする場合、通常、指令値と実際のセンサーフィードバック間の不一致を示します。
完全アラーム一覧: 4014 Siemens SINUMERIK 840D CNC コードs.
Have a better solution?
Help the industrial community by sharing your repair experience for code 17502.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026