代碼 201012: <location>Project conversion error
問題描述與安全警告
Siemens SINUMERIK 840D CNC 觸發了嚴重的 <location>Project conversion error 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Message value: %1 Drive object: SERVO, VECTOR Reaction: OFF2 (NONE) Acknowledge: IMMEDIATELY Cause: When converting the project of an older firmware version, an error occurred. Fault value (r0949, interpret decimal): Parameter number of the parameter causing the error. For fault value = 600, the following applies: The temperature evaluation is no longer assigned to the power unit but to the encoder evaluation. Notice: Monitoring of the motor temperature is no longer ensured. Remedy: Check the parameter indicated in the fault value and correctly adjust it accordingly. Re fault value = 600: Parameter p0600 must be set to the values 1, 2 or 3 in accordance with the assignment of the internal encoder evaluation to the encoder interface. Value 1 means: The internal encoder evaluation is assigned to the encoder interface 1 via p0187. Value 2 means: The internal encoder evaluation is assigned to the encoder interface 2 via p0188. Value 3 means: The internal encoder evaluation is assigned to the encoder interface 3 via p0189. If necessary, the internal encoder evaluation must be assigned to an encoder interface via parameters p0187, p0188 or p0189 accordingly. - If necessary, upgrade the firmware to a later version.
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Siemens SINUMERIK 840D CNC 警報
由 Siemens 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 SINUMERIK 840D CNC 出現類似 201012 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 4014 Siemens SINUMERIK 840D CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 201012.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026