Code 205002: <location>Power unit: Air intake overtemperature
Issue Description & Safety Warning
The Siemens SINUMERIK 840D CNC has triggered a critical <location>Power unit: Air intake overtemperature alarm. Immediate attention from a qualified operator or maintenance technician is required to prevent secondary damage to the equipment or spoiled parts during the manufacturing cycle. Always ensure standard safety and LOTO procedures are followed before accessing electrical cabinets.
Official Troubleshooting Steps
Message value: Drive object: A_INF, B_INF, S_INF, SERVO, VECTOR Reaction: NONE Acknowledge: NONE Cause: The alarm threshold for the air intake overtemper ature has been reached. For air-cooled power units, the threshold is 42 °C (hysteresis 2 K). The response is set using p0290. If the air intake temperature increases by an additional 13 K, then fault F30035 is output. Remedy: Check the following: - is the ambient temperature wi thin the defined limit values? - has the fan failed? Check the direction of rotation.
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
About Siemens SINUMERIK 840D CNC Alarms
Siemens controllers include extensive self-diagnostics that flag or halt the machine when a fault is detected. Error code 205002 on the SINUMERIK 840D CNC identifies one specific fault condition — its documented cause and the official corrective steps are listed above, sourced from Siemens's service documentation. Always confirm against the manual for your exact machine configuration and follow LOTO procedures before servicing.
Complete Alarm List: 4014 Siemens SINUMERIK 840D CNC codes.
Have a better solution?
Help the industrial community by sharing your repair experience for code 205002.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026