コード 206000: <location>Infeed: Precharg ing monitoring time expired

問題の説明と安全警告

Siemens SINUMERIK 840D CNC は重大な <location>Infeed: Precharg ing monitoring time expired アラームをトリガーしました。製造サイクル中に機器への二次的損傷や部品の破損を防ぐために、資格のあるオペレーターまたはメンテナンス技術者による直ちの対応が必要です。電気キャビネットにアクセスする前に、必ず標準の安全およびLOTO手順が遵守されていることを確認してください。

公式トラブルシューティング手順

Message value: Drive object: A_INF, B_INF, S_INF Reaction: OFF2 (OFF1) Acknowledge: IMMEDIATELY Cause: After the line contactor closes the power unit does not signal the READY state within the monitoring time (p0857). The end of the DC link pre-charging was not able to be completed for one of the following reasons: 1) There is no line supply voltage connected. 2) The line contactor/line side switch has not been closed. 3) The line supply voltage is too low. 4) Line supply voltage incorrectly set (p0210). 5) The pre-charging resistors are overheated as t here were too many pre-charging operations per time unit. 6) The pre-charging resistors are overheated as the DC link capacitance is too high. 7) The pre-charging resistors are overheated because when there is no "ready for operation" (r0863.0) of the infeed unit, power is taken from the DC link. 8) The pre-charging resistors are overheated as the line contactor was closed during the DC link fast discharge through the Braking Module. 9) The DC link has either a ground fault or a short-circuit. 10) The pre-charging circ uit is possibly defective (only for chassis units). See also: p0210, p0857 SINAMICS-Alarms Remedy: In general: - check the line supply voltage at the connecting terminals. - check the line supply voltage setting (p0210). - check the monitoring time and, if required, increase (p0857). - where relevant, observe additional pow er unit messages/signals (e.g. F30027). - the following applies to booksize units: Wait (approx. 8 min.) until the pre-charging resistors have cooled down. The infeed unit must be disconne cted from the supply for this purpose. Re 5): - carefully observe the permissibl e pre-charging frequency (refer to the appropriate Equipment Manual). Re 6): - check the total capacitance of the DC link and if required, correspondingly reduce the maximum permissible DC link capacitance (refer to the appropriate Equipment Manual). Re 7): - interconnect the ready for operation signal of the in feed unit (r0863.0) in the enable logic of the drives connected to this DC link. Re 8): - check the connections of the ex ternal line contactor. The line contactor must be open during the DC link fast discharge. Re 9): - check the DC link regarding ground fault or short-circuit.

Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)

Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.

Siemens SINUMERIK 840D CNC のアラームについて

Siemens によって構築された産業用コントローラーは、内部回路と機械的リンケージを保護するための広範な診断システムで設計されています。SINUMERIK 840D CNC が 206000 のようなエラーコードをスローする場合、通常、指令値と実際のセンサーフィードバック間の不一致を示します。

完全アラーム一覧: 4014 Siemens SINUMERIK 840D CNC コードs.

Have a better solution?

Help the industrial community by sharing your repair experience for code 206000.

Manual conversion service

Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?

We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.

Convert PDF fault-code charts and manuals into clean data.
Build public SEO pages or private internal search tools.
Prioritize updates around codes and manuals people search for.
Request manual conversion Email PDFs to manuals.errordb@gmail.com
Advertisement

Space reserved for Google AdSense / Industrial Affiliate Links

Monetization target for 2026

関連する Siemens SINUMERIK 840D CNC コード