代碼 206200: <location>Infeed: Failure of one or several line phases
問題描述與安全警告
Siemens SINUMERIK 840D CNC 觸發了嚴重的 <location>Infeed: Failure of one or several line phases 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Message value: Drive object: A_INF, S_INF Reaction: OFF2 (OFF1) Acknowledge: IMMEDIATELY (POWER ON) Cause: Failure overvoltage in one or several line supply phases. The fault can be output in two operating states: 1. During the power-on phase of the infeed unit. The measured line supply angle deviates from the regul ar characteristic for a 3-phase system - the PLL cannot be synchronized. The fault occurs immediately after power-up if, wh en operating with a VSM, the phase assignment L1, L2, L3 at the VSM differs from t he phase assignment at the power unit. 2. While the infeed is operational. After a voltage dip has been detected or an overvolt age (note A06205) in one or several line phases a fault occurred within 100 ms (also refer to other relevant messages). Generally, before fault message F06200 is output, Alarm A06205 occurs at leas t once, whose warning value can provide information regarding the cause of the line supply fault. Probable causes of the fault: - voltage dip on the line side or phase failure or overvoltage lasting longer than 10 ms. - overload condition on the load side with peak current. - commutating reactor missing. Remedy: - check the line supply and fuses. - check the connection and size (rating) of the line commutating reactor. - check and correct the phase assignment at the VSM (X521 or X522) and at the power unit. - check the load. - if failed in operation, carefully note the prev ious alarm messages A 6205 with alarm values. See also: p3463 (Infeed, line angle change, phase failure detection) SINAMICS-Alarms
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.
關於 Siemens SINUMERIK 840D CNC 警報
由 Siemens 製造的工業控制器具有廣泛的診斷系統,用於保護內部電路和機械連桿。當 SINUMERIK 840D CNC 出現類似 206200 的錯誤代碼時,通常表示指令值與實際感測器回饋之間存在不匹配。
完整警報清單: 4014 Siemens SINUMERIK 840D CNC 代碼s.
Have a better solution?
Help the industrial community by sharing your repair experience for code 206200.
Need a searchable reference for more Siemens SINUMERIK 840D CNC manuals?
We structure equipment manuals into searchable code, title, cause, solution, safety note, and source-reference data. Send a PDF and example searched codes when you need public pages, private search, or structured exports.
Space reserved for Google AdSense / Industrial Affiliate Links
Monetization target for 2026