問題描述與安全警告
Siemens SINUMERIK 840D CNC 觸發了嚴重的 <location>Infeed: Line supply overvoltage 警報。需要由合格的操作員或維修技師立即處理,以防止在製造週期中對設備造成二次損壞或導致零件報廢。在接觸電氣控制箱之前,請務必確保遵循標準安全和停機掛牌 (LOTO) 程序。
官方故障排除步驟
Message value: Line supply voltage: %1 Drive object: A_INF, B_INF, S_INF Reaction: NONE Acknowledge: NONE Cause: The filtered (steady-state) value of the rms line supply voltage Vrms is higher than the alarm threshold (p0281). Alarm condition: Vrms > p0281 * p0210. Alarm value (r2124, floating point): Current steady-state line supply voltage. See also: p0281 (Line supply overvoltage, alarm threshold) Remedy: - check the line supply. - check the line supply voltage (p0210). - check the alarm threshold (p0281). See also: p0210, p0281
Source: SINUMERIK 840D sl / 840Di sl / SINAMICS S120 Diagnostics Manual (DAsl, 03/2009)
Last reviewed: 2026-07-01 · Verified against the manufacturer’s official documentation.